STR-D360Z/DE315/DE415
US Model
Canadian Model
STR-D360Z/DE315/DE415
Australian Model
STR-DE315/DE415
E Model
Chinese Model
STR-DE315
SERVICE MANUAL
FM STEREO/FM-AM RECEIVER
MICROFILM
Manufactured under license from Dolby Laboratories
Licensing Corporation.
"DOLBY" and the double-D symbol
a are trademarks
of Dolby Laboratories Licensing Corporation.
SPECIFICATIONS
-- Continued on next page --
Photo : STR-DE315 model
-- 2 --
TABLE OF CONTENTS
Specifications ··············································································· 1
1.
GENERAL
Location and Function of controls ················································ 4
2.
EXPLANATION OF IC TERMINALS ··················· 5
3.
DIAGRAMS
3-1.
Circuit Boards Location ····················································· 7
3-2.
Printed Wiring Boards (MAIN SECTION) ························ 9
3-3.
Schematic Diagram (MAIN SECTION) ·························· 13
3-4.
Schematic Diagram (DISPLAY SECTION) ···················· 18
3-5.
Printed Wiring Boards (DISPLAY SECTION) ················ 21
4.
EXPLODED VIEWS
4-1.
Front Panel Section ·························································· 25
4-2.
Chassis Section ································································· 27
5.
ELECTRICAL PARTS LIST ································ 29
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
I/O
O
O
O
O
O
O
O
--
I
I
I
O
O
--
--
I
I
I
I
--
O
O
O
--
I
I
I
I
--
--
--
--
--
--
--
O
O
O
O
O
Description
Fluorescent indicator tube drive.
Power supply (+5V).
System clock.
System data.
PLL data input from TU001.
Chip enable output.
Chip enable output.
Not used.
Not used. (Open)
Protector detect input.
System reset terminal.
Auto stop detect input.
Stereo detect input.
Ground.
Speaker relay drive.
Surround Relay.
Power relay drive.
Not used.
A/D signal input terminal.
A/D3 key input terminal.
A/D2 key input terminal.
A/D1 key input terminal.
Power supply (+5V).
Reference voltage (+5V).
Ground.
Not used (Open).
Ground.
System clock (4.19MHz).
System clock (4.19MHz).
Mute drive output for
µPD2581V (IC701).
Plologic LED.
CINEMA STUDIO LED.
HALL LED.
Tuner mute drive output.
Pin Name
DIG7
DIG6
DIG5
DIG4
DIG3
DIG2
DIG1
+5V
S. CLK
S. DATA
PLL. DATA
S. CE (LC7288)
S. CE (LV100)
REARRY
BRIDGE CABLE
PROTECT
RESET
AUTO-STOP
STEREO-IN
AVss
SP-RY
SURR-RY
POWER-RY
Not used
SIGNAL
A/D3
A/D2
A/D1
AVDD
AV. REF
GND
NC
Vss
X1
X2
IC. MUTE
PROLOGIC
CSTUDIO
HALL
T. MUTE
SECTION 2
EXPLANATION OF IC TERMINALS
Pin No.
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
I/O
O
O
O
I
I
I
I
--
I
I
--
--
--
O
--
I
I
I
I
I
--
O
O
O
O
O
O
O
O
O
--
O
O
O
O
O
O
O
O
O
Description
Volume up.
Volume down.
Standby LED drive.
System power ON/OFF.
RDS data input. (AEP, SP. MY, CH model)
RDS clock input. (AEP, SP, MY, CH model)
Stop signal input from NJM2103D (IC950).
Ground.
Sircs signal input.
Power switch input terminal.
Not used,
Power supply (+5V).
Bass boost LED drive.
Line mute drive.
Not used.
Input for model select.
Key in 4.
Key in 3.
Key in 2.
Key in 1.
Not used.
Key out 1
Key out 2
Key out 3
Key out 4
Connect to 24V.
Fluorescent indicator tube drive.
Pin Name
VOLUME UP
VOLUME DOWN
STANDBY
SYS. POWER
RDS. DATA. IN
RDS. CLK. IN
STOP
Vss
SIRCS
POWER SW
5.1ch LED
+5V
BASS BOOST
FUNC. MUTE
SL MUTE
VERSION
K14
K13
K12
K11
SR MUTE
S15
S14
S13
S12
S11
S10
S9
S8
S7
VLOAD
S6
S5
S4
S3
S2
S1
DIG10
DIG9
DIG8
SECTION 3
DIAGRAMS
Fluorescent indicator tube drive.
3-1.
CIRCUIT BOARDS LOCATION
-- 3 --
-- 4 --
-- 5 --
-- 6 --
-- 7 --
· IC201
µPD78044FGF-041-3B9
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2.
A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
SAFETY CHECK-OUT
To Exposed Metal
Parts on Set
0.15
µF
1.5k
AC
voltmeter
(0.75V)
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK
! OR DOTTED LINE WITH
MARK
! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUB-LISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE
! SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
SECTION 1
GENERAL
LOCATION AND FUNCTION OF CONTROLS
SP SW (A)
PRIMARY
SECONDARY
SELECTOR
STBY
VIDEO
VOLUME
VR TONE
KEY
DISPLAY
SP SW (B)
SW
MAIN
D360Z
DE315
DE415
US, Canadian model : AC 120V 60Hz
Australian model : AC 240V ~50/60Hz
E model : AC 120, 220, 240V selectable ~50/60Hz
Singapore, Malaysia,
Chinese model : AC 230V ~50/60Hz
MODEL IDENTIFICATION
MODEL NO.
FM STEREO/FM-AM RECEIVER
STR -