background image
Indice
1.
Safety instructions ............................................................................................................................................1
2.
WARNING ........................................................................................................................................................1
3.
Precaution against X-Rays ...............................................................................................................................1
4.
Recommendations to protect our environment ................................................................................................1
5.
TECHNICAL CHARATERISTICS.....................................................................................................................2
6.
Safety................................................................................................................................................................2
7.
EMC (Electromagnetic Compatibility) ...............................................................................................................2
8.
Factory special mode........................................................................................................................................2
9.
Automatic channel search reactivating .............................................................................................................3
10.
Service Menu ................................................................................................................................................3
11.
CONNECTED DOCUMENTS. ......................................................................................................................3
12.
MOUNTED CIRCUITS CODES. ...................................................................................................................3
13.
CABINET PARTS LIST .................................................................................................................................4
13.1.
CABINET PARTS LIST OF CHASSIS CE29FFV1-F.............................................................................4
13.2.
CABINET PARTS LIST OF CE29FFV1-F .............................................................................................5
14.
PARTS LIST..................................................................................................................................................6
CE29FFV1-F
Service Manual
Model:
CRT 29" Philips A68ERF001X013
CHASSIS 2114
EB5-C 21"/25"/28"/29"
Colour Television True Flat
Give complete "SERVICE PART No" for parts order or
servicing, it is shown on the rating sheet on the cabinet
back of the TV set.
Note
This TV receiver will not work properly in foreign countries
where the television transmission system and power
source differ from the design specifications. Refer to the
specifications for the design specifications.
Ref. Nº MS CE29FFV1-F
03-07-2002


background image
Service Manual SM CE29FFV1-F
1
1. Safety instructions
Read this page before doing any operation of adjustment, maintenance or repair the TV set described.
Only skilled personnel of Sanyo Technical Service should do the adjustment, maintenance or repair of TV set.
2. WARNING
For the correct and safe use of the TV set, it is essential that the service personnel follow the process of safety
generally accepted and the safety precautions specified in this manual.
An isolation transformer should be connected in the power line between the receiver and the AC line when a service
is performed on the primary side of the converter transformer of the set.
The deflection heat sink is connected to -12V.
3. Precaution against X-Rays
The primary source of X-RADIATION in the television receiver is the picture tube. The picture tube is specially
constructed to limit X-RADIATION emissions. For continued X-RADIATION protection, the replacement tube must
be the same type as the original including suffix letter. Excessive high voltage may produce potentially hazardous X-
RADIATION. To avoid such hazards, the high voltage must be maintained within specified limit. If high voltage
exceeds specified limits, take necessary corrective action. Follow the instructions carefully for +B1 volt power supply
adjustment, and high voltage adjustment to maintain the high voltage within the specified limits.
COMPLIANCE TO STANDARDS
All of those marked with
! or
must be
Replaced with original parts
WARNING! This TV set contains components which
are particularly sensitive to static electricity (ESD).
It is recommended that all due precaution be taken
handling integrated circuits and semiconductors.
4. Recommendations to protect our environment
Stand-by mode: In order to save energy and to maintain an optimum picture quality, it is advisable to switch off the
TV using the ON/OFF button located at the front of TV set.
Used batteries: The batteries in the remote control of these models do not contain mercury. However, SANYO
recommends that you do not dispose of used batteries in domestic refuse. Please, contact your dealer or your local
authorities for information regarding the disposal of used batteries or your nearest collection point.
Recommendation about the end-of-life: These SANYO TV sets have been designed and manufactured using high
quality materials which can be recycled and reused. In the future, when the life cycle of these sets come to an end,
specialised companies can disassemble it and reuse certain materials. This reduces the impact of waste in our
environment. Please, contact with your local authorities for information regarding the disposal of your set when the
time arrives. Help us to conserve the environment we live in!


background image
Service Manual SM CE29FFV1-F
2
5. TECHNICAL CHARATERISTICS.
Cathode-ray tubes
In-Line, gun Type. Black Matrix. 29" (68 cm) True Flat, Invar Plus mask.
Tuning-system
Voltage synthesis, 100 programs in non-volatile memory, AFT, automatic,
semiautomatic and manual channel-search.
Reception channels
Band I, channels 2-4 (VHF)=E2-E4
Cable channels S1-S10
Hyperband channels S21-S41
Band III, channels 5-12 (VHF)=E5-E12
Band IV-V, channels 21-69 (UHF)=E21-E69
Reception system
B/G, D/K, I, L, L' system
Colour system
PAL, SECAM, (NTSC 4.43, NTSC 3,58) ONLY AV
Program selection
Sequential selection from the controls on the set. Direct selection to any program
from the remote-control device.
Audio
Power-rating 2x8,9 W rms. (10% distortion)
Speakers
2 of 8
.
Aerial
External aerial sockets 75
s. IEC
Jack for headphones
Stereo jack 3,5mm. (with independent control)
Clock and alarm Function
Timer Function
Switch on and off of CTV programmable in real time.
AV connectors
1 Scart connector 21 pin CENELEC standard AV, RGB and S_Video.
1 Scart connector 21 pin CENELEC standard AV, RGB
1 RCA Video input (frontal)
2 RCA Audio input (frontal)
Power supply
220 ­ 240 VAC 50Hz
Consumption
83 W (IEC 107-1)
2,1 W (Stand-by
)
CTI
Improves color transitions
Comb Filter
Improves video bandwith and reduces crosscolor effect.
Stereo/Dual Systems
NICAM and Stereo/Dual (A2)
Sound Effects
Pseudo Stereo. Bass boost. Actv. 3D sorround, BBE, spatial stereo
Auto volume
Clock function
Alarm function
Programmable over 24 hours
Timer function
Switch on and off are programmable aver 24 hours.
TXT
1,5 Flot and list. 10 Teletext pages memory
Hotel Mode
It can be programmed in Hotel Mode and Rental Hotel Mode
Remore ON/OFF
Tis TV can be switched ON/OFF Through the blue scart connector.
Options by means of Technical Service:
SECAM, NTSC-M
6. Safety
It fulfils the safety requirements established in the regulation:
EN 60065:98
7. EMC (Electromagnetic Compatibility)
It fulfils the EMC requirements established in the regulation:
EN 55013:1990/A12:1993/A13:1996/A14:1999
EN 55020:1994/A11:1996/A13:1999/A14:1999
EN 61000-3-2:1995+A1:19998+A2:98/A14:2000
EN 61000-3-3:1995
8. Factory special mode
The factory mode is a special TV working mode intended to help in the manufacturing process and it is identified on
the screen with the message "FAC". This mode is never suited for customer use.
The main differences respect to normal mode are:
1- The standby mode is always disabled.
2- The Blue-back (no sync. signal present) is disabled.
3- The customer adjustments ( volume, contrast ...) work faster.
4- The timer off works but it does not change to Stand-by mode.
5- Change of programs and TV/AV swithing faster. Cancelled mute.
In case of finding the TV set in Factory mode, it must be taken out of this state. To do so, enter the clock setting
menu on the customer OSD and then exit.


background image
Service Manual SM CE29FFV1-F
3
9. Automatic channel search reactivating
In order to reset the initial automatic channel search function, start a channel search in AUTO mode from the user
tuning menu and switch-off the TV set before any station is found. The next time the TV set is switched on, it will
start an automatic channel-search.
10. Service Menu
The service menu allows to acces to de relationel parameters with the TV setting.
The service menu is accessed by holding down the front key (vol-) and simultaneously pressing the teletext green
key from the remote control. An very detaill explication is in the Service Manual of chassis 2114 (EB5-C).
11. CONNECTED DOCUMENTS.
This Service Manual provides the particular information of the model CE29FFV1-F and it is complemented with:
1.
Service Manual of the CHASIS 2114 (EB5-C).
2.
Service Electrical scheme of the model CE29FFV1.
3.
Instruction manual.
12. MOUNTED CIRCUITS CODES.
CE29FFV1-F
A68ERF001X013
Assy
6110385702
Main + Socket TRC +Audio + Mandos
Subassy
7040004207
Socket TRC PCB
Subassy
7110024408
Main PCB
Subassy
7140002135
Audio PCB
Subassy
7200002108
PCB Mandos


background image
Service Manual SM CE29FFV1-F
4
13. CABINET PARTS LIST
13.1.
CABINET PARTS LIST OF CHASSIS CE29FFV1-F
Ref. No.
Part No.
Description
YG25
0390320307 Bar Code Label -Chassis
YG4
"
0080113103 COMP. Side IF Shield EB5-C
YG5
0080113202 Copper Side IF Shield EB5-C
YG1800
0200826402 LED Holder
Assy PA (Audio)
IC300
0360517304 TDA 8946 J N1
YR300
0200226108 Heatsink AUDIO EB5-C 25-28-29
YR301
0970200804 Silicon Grease YG6260
YR302
0010106300 Spring CLIP 56379
Assy PD (Deflexión)
IC701
"
0360517007 LA7846N
Q650
0360306708 S 2055 N
Q750
0360309009 BD242BFP
YR650
0200225902 Heatsink Deflection EB5-C 29
YR651
0970200804 Silicon Grease YG6260
YR652
0010106300 Spring CLIP 56379
YR653
0010106300 Spring CLIP 56379
YR654
0010110401 Spring CLIP 56363
Assy PB
D851
0360378905 Schottky FMB-G19L 90V 4ATO220
YR851
0200224905 Heatsink TO-220-F
Localiz.
Código
Descripción
Assy PF(Fuente alimentación)
Q800
"
0360311302 MOS 2SK2545 600V/6A
YR800
0200225811 Heatsink Power Supply EB5-C
YR801
0010110401 Spring CLIP 56363
Assy PT
S901
0330162702 Scart Connector 21 PIN BLUE
YR901
0200420602 Mounting-BRKT F2WV
YR902
0890115603 Selftapping Screws DIN 7981F 2,9X8
Assy PS
S900
0330162603 Scart Connector 21 PIN BLACK
YR900
0200420602 Mounting-BRKT F2WV
YR903
0890115603 Selftapping Screws DIN 7981F 2,9X8
Assy PC (Zocalo TRC)
IC500
0360514210 TDA 6107 Q/N2
YR500
0200224806 Heatsink RGB EB5-A
YR501
0970200804 Silicon Grease YG6260
YR502
0050709104 Washer
YR503
0890121106 Screw M3X6 FE/ZN DIN 7985