background image
BEDIENUNGSANLEITUNG : FARB-VIDEO-MONITOR
MANUEL D'INSTRUCTIONS : MONITEUR VIDEO COULEUR
MANUALE DI ISTRUZIONI : MONITOR VIDEO A COLORI
INSTRUCCIONES : MONITOR DE VIDEO A COLOR
INSTRUCTIONS
TM-H150CG
COLOR VIDEO MONITOR
ESPAÑOL
ITALIANO
FRANÇAIS
DEUTSCH
ENGLISH
LCT1564-001A-H
For Customer Use:
Enter below the Serial No. which is located on the rear of the cabinet.
Retain this information for future reference.
Pour l'usage du client:
Enter ci-dessous le numéro de série qui est situé sur l'arrière du coffret.
Conserver cette information pour une référence ultérieure.
Model No. :
Numéro de modèle :
Serial No. :
Numéro de série :
TM-H150CG_Cover.p65
04.1.17, 4:05 PM
3


background image
ENGLISH
INSTRUCTIONS
COLOR VIDEO MONITOR
TM-H150CG
Thank you for purchasing this JVC color video monitor. Before using it, read and follow all
instructions carefully to take full advantage of the monitor's capabilities.
TM-H150CG_Cover.p65
04.1.17, 4:05 PM
5


background image
In order to prevent any fatal accidents caused by misoperation
or mishandling the monitor, be fully aware of all the following
precautions.
WARNINGS
To prevent fire or shock hazard, do not expose this
monitor to rain or moisture. Dangerous high voltages
are present inside the unit. Do not remove the back
cover of the cabinet. When servicing the monitor,
consult qualified service personnel. Never try to service
it yourself.
WARNING : THIS APPARATUS MUST
BE EARTHED.
PRECAUTIONS
Use only the power source specified on the unit.
(120 V AC/220 ­ 240 V AC, 50 Hz/60 Hz)
When not using this unit for a long period of time, or when
cleaning it, be sure to disconnect the power plug from the
AC outlet.
Do not allow anything to rest on the power cord. And do not
place this unit where people will tread on the cord. Do not
overload wall outlets or power cords as this can result in a
fire or electric shock.
Avoid using this unit under the following conditions:
­ in extremely hot, cold or humid places,
­ in dusty places,
­ near appliances generating strong magnetic fields,
­ in places subject to direct sunlight,
­ in badly ventilated places,
­ in automobiles with doors closed.
Do not cover the ventilation slots while in operation as this
could obstruct the required ventilation flow.
When dust accumulates on the screen surface, clean it with
a soft cloth.
Unplug this unit from the AC outlet and refer servicing to
qualified service personnel under the following conditions:
­ when the power cord is frayed or the plug is damaged,
­ if liquid has been spilled into the unit,
­ if the unit has been dropped or the cabinet has been
damaged,
­ when the unit exhibits a distinct change in performance.
Do not attempt to service this unit yourself as opening or
removing covers may expose you to dangerous voltage or
other hazards. Always refer servicing to qualified service
personnel.
When replacement parts are required, have the service
personnel verify in writing that the replacement parts he/
she uses have the same safety characteristics as the
original parts. Use of manufacture's specified replacement
parts can prevent fire, shock, or other hazards.
Upon completion of any servicing or repair work to this unit,
please ask the service personnel to perform the safety
check described in the manufacturer's service literature.
When this unit reaches the end of its useful life, improper
disposal could result in a picture tube implosion. Ask
qualified service personnel to dispose of this unit.
This monitor is equipped with a 3-blade grounding-type
plug to satisfy FCC rule. If you are unable to insert the
plug into the outlet, contact your electrician.
FCC INFORMATION (U.S.A. only)
CAUTION: Changes or modification not approved by
JVC could void the user's authority to operate the
equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
­ Reorient or relocate the receiving antenna.
­ Increase the separation between the equipment and
receiver.
­ Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
­ Consult the dealer or an experienced radio/TV
technician for help.
SAFETY PRECAUTIONS
Notice (U.S.A. only)
This product utilizes both a Cathode Ray Tube (CRT) and
other components that contain lead. Disposal of these
materials may be regulated in your community due to
environmental considerations. For disposal or recycling
information please contact your local authorities, or the
Electronics Industries Alliance: <http://www.eiae.org.>
2
Improper operations, in particular alternation of high
voltage or changing the type of tube may result in x-ray
emission of considerable dose. A unit altered in such a
way no longer meets the standards of certification, and
must therefore no longer be operated.
TM-H150CG_Cover.p65
04.1.17, 4:05 PM
6


background image
ENGLISH
Contents
SAFETY PRECAUTIONS ................................................................................. 2
Controls and Features .................................................................................... 4
Front Panel .................................................................................................... 4
Rear Panel ..................................................................................................... 6
Input Card (option) ......................................................................................... 7
Preparation ...................................................................................................... 9
Installing the Input Card ................................................................................. 9
Basic Menu Operations (MENU, SET-UP MENU)............................................................... 10
How to Use MENU ......................................................................................... 12
How to Use SET-UP MENU ........................................................................... 13
How to Use the External Control .................................................................. 15
Troubleshooting ............................................................................................ 16
Specifications ................................................................................................ 18
SCREEN BURN
It is not recommended to keep a certain still image displayed on screen for a long time as well as displaying extremely bright
images on screen. This may cause a burning (sticking) phenomenon on the screen of cathode-ray tube. This problem does not
occur as far as displaying normal video playback motion images.
Supplementary Explanation
= Information for monitor operation =
This monitor uses a high precision CRT (cathode ray tube). Please follow the procedures below.
* For stable operation of the CRT, approximately 30 minutes running time is required from the time the power is turned on.
* When the monitor is installed, it can be easily affected by surrounding magnetic fields, which can generate irregular color
on the screen. When it is difficult to eradicate, degauss from outside using a degausser, etc.
Fuse
POWER CONNECTION
The power supply voltage rating of this product is AC 120 V (For U.S.A. and Canada only) and AC 220 ­ 240 V (For European
countries or United Kingdom), the power cord attached conforms to the following power supply voltage and countries. Use only the
power cord designated to ensure Safety and EMC regulations of each countries.
Power cord
Power supply voltage : AC 120 V
AC 220 ­ 240 V
AC 220 ­ 240 V
Countries
: U.S.A. and Canada
European countries
United Kingdom
Warning:
Do not use the same Power Cord for AC 120 V as for AC 220 ­ 240 V. Doing so may cause malfunction, electric shock
or fire.
Note for the United Kingdom power cord only
The plug on the United Kingdom power cord has a built-in fuse. When replacing the fuse, be sure to use only a correctly rated
approved type, re-fit the fuse cover.
(Consult your dealer or qualified service personnel.)
How to replace the fuse
Open the fuse compartment with the blade screw driver, and
replace the fuse.
(* An example is shown in the illustration.)
3
TM-H150CG_Cover.p65
04.1.17, 4:05 PM
7


background image
4
Controls and Features
Front Panel
1 CHROMA ( : Chroma)/PHASE (
: Phase)
button*
Press this button to activate the Chroma (picture
color density) adjustment mode or the Phase
(picture hue) adjustment mode. Each time you
press the button, the adjustment modes change.
Chroma
"Phase
Adjust the value with the VOLUME/SELECT
+) buttons while the level bar appears on the
screen.
(­40 to +40)
· CHROMA is not adjustable when the RGB signal, black-
and-white signal, or no signal is input (except the
component signal).
· Adjusting CHROMA to "­40" is chroma off.
· PHASE is adjustable only when the NTSC signal is input.
fi button (while the menu screen is displayed)
Selects the items on the menu screen.
2 CONTRAST ( :Contrast)/
BRIGHT (
:Brightness) button*
Press this button to activate the picture contrast
adjustment mode or picture brightness adjustment
mode. Each time you press the button, the
adjustment modes change.
Contrast
"Brightness
Adjust the value with the VOLUME/SELECT
+) buttons while the level bar appears on the
screen.
(­40 to +40)
% button (while the menu screen is displayed)
Selects the items on the menu screen.
* While adjusting the picture,
· The adjustment level bar disappears if no operation has
been done for about 10 seconds.
· The adjustment level bar also disappears if you press
MENU button.
·"NO EFFECT" will appear for about 3 seconds if the
function you select has no effect.
3 VOLUME/SELECT (­
+) buttons
Adjusts the volume.
These buttons are also used to select the items on
the menu screen while the menu screen is
displayed.
· Pressing + or ­ button displays the VOLUME level bar on
the screen. Pressing + or ­ button while the level bar
appears on the screen allows you to adjust the volume.
(00 to 50)
· The VOLUME level bar disappears if no operation has
been done for about 10 seconds.
· The VOLUME level bar also disappears if you press
MENU button.
4 MENU button
Displays MENU.
\ For details, see page 10.
NOTE:
To display SET-UP MENU, press the
fi button while holding down
the MENU button.
5 UNDER SCAN button
Reduces the screen size to display the entire
image.
· The button lights while this function is activated.
· Pressing the button again restores the screen to normal
size.
6 COLOR OFF button
Cuts color signals to display a black and white
image.
Use this function to check noises in the luminance
signal or to check the white balance adjustment.
· The button lights while this function is activated.
· Pressing the button again restores the normal screen.
NOTE:
This function is not available to the RGB signal.
12
3
4
5
6
7
8
9
p
q
w
[04-09]_TM-H150CG.p65
04.1.17, 4:05 PM
4