TH-V70
No.21089
Jul. 2002
COPYRIGHT
2002 VICTOR COMPANY OF JAPAN, LTD.
SERVICE MANUAL
Contents
Safety precautions
Preventing static electricity
Importance administering point
on the safety
1-2
1-3
1-4
1-6
1-21
1-22~54
Disassembly method
Adjustment method
Description of major ICs
TH-V70
Area suffix
J ----------------------------- U.S.A.
C -------------------------- Canada
DVD DIGITAL THEATER SYSTEM
SP-PWV70
XV-THV70
SP-XCV70
SP-XSV70
SP-XSV70
SP-XSV70
SP-XSV70


background image
TH-V70
1-2
1. This design of this product contains special hardware and many circuits and components specially for safety
purposes. For continued protection, no changes should be made to the original design unless authorized in
writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services
should be performed by qualified personnel only.
2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product
should not be made. Any design alterations or additions will void the manufacturer`s warranty and will further
relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.
3. Many electrical and mechanical parts in the products have special safety-related characteristics. These
characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily
be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which
have these special safety characteristics are identified in the Parts List of Service Manual. Electrical
components having such features are identified by shading on the schematics and by (
) on the Parts List in
the Service Manual. The use of a substitute replacement which does not have the same safety characteristics
as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or
other hazards.
4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be
separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of
electric shock and fire hazard. When service is required, the original lead routing and dress should be
observed, and it should be confirmed that they have been returned to normal, after re-assembling.
5. Leakage currnet check (Electrical shock hazard testing)
After re-assembling the product, always perform an isolation check on the exposed metal parts of the product
(antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the
product is safe to operate without danger of electrical shock.
Do not use a line isolation transformer during this check.
Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the leakage
current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return
path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).
Alternate check method
Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more
sensitivity in the following manner. Connect a 1,500
10W resistor paralleled by a 0.15 F AC-type capacitor
between an exposed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal part,
particularly any exposed metal part having a return path to
the chassis, and meausre the AC voltage across the resistor.
Now, reverse the plug in the AC outlet and repeat each
measurement. Voltage measured any must not exceed 0.75 V
AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.).
1. This equipment has been designed and manufactured to meet international safety standards.
2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.
3. Repairs must be made in accordance with the relevant safety standards.
4. It is essential that safety critical components are replaced by approved parts.
5. If mains voltage selector is provided, check setting for local voltage.
Good earth ground
Place this
probe on
each exposed
metal part.
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
1500
10W
0.15 F AC TYPE
!
Burrs formed during molding may
be left over on some parts of the
chassis. Therefore, pay attention to
such burrs in the case of
preforming repair of this system.
In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the
parts that are printed over with black such as the resistor (
), diode (
) and ICP (
) or identified by the " "
mark nearby are critical for safety.
(This regulation does not correspond to J and C version.)


background image
TH-V70
1-3
Conductive material
(conductive sheet) or iron plate
(caption)
Anti-static wrist strap
Short lands
DVD servo board
Flexible wire
CN202
CN201
DVD mechanism assembly
Connector
5. Attention when traverse unit is decomposed
*Please refer to "Disassembly method" in the text for the DVD pickup unit.
Apply solder to the short lands before the flexible wire is disconnected
from the connector on the DVD servo board.
(If the flexible wire is disconnected without applying solder, the DVD
pickup may be destroyed by static electricity.)
In the assembly, be sure to remove solder from the short lands after
connecting the flexible wire.
Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged,
can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.
Preventing static electricity
1. Grounding to prevent damage by static electricity
Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as DVD players.
Be careful to use proper grounding in the area where repairs are being performed.
2. About the earth processing for the destruction prevention by static electricity
Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it
before placing the traverse unit (optical pickup) on it.
2-1 Ground the workbench
2-2 Ground yourself
Use an anti-static wrist strap to release any static electricity built up in your body.
In order to maintain quality during transport and before installation, both sides of the laser diode on the
replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition.
(Refer to the text.)
Do not use a tester to check the condition of the laser diode in the optical pickup. The tester's internal power
source can easily destroy the laser diode.
3. Handling the optical pickup
1.
2.
Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit.
Remove solder of the short lands on the flexible wire after replacing the optical pickup. For specific details, refer
to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit.
Be careful not to take too long a time when attaching it to the connector.
Handle the flexible wire carefully as it may break when subjected to strong force.
It is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.
4. Handling the traverse unit (optical pickup)
1.
2.
3.
4.


background image
TH-V70
1-4
Importance administering point on the safety
Main board
<Main body section>
Caution: For continued protection against risk of
fire, replace only with same type 1.6A/125V for F901.
This symbol specifies type of fast operating fuse.
Precaution: Pour eviter risques de feux, remplacez
le fusible de surete de F901 comme le meme type
que 1.6A/125V.
Ce sont des fusibles suretes qui functionnes rapide.
F901


background image
TH-V70
1-5
<Speaker section>
Power supply & SP terminal board
F403
F505
Mother board
F504
Caution: For continued protection against risk of
fire, replace only with same type 4A/125V for F403,
8A/125V for F504, 8A/125V for F505.
This symbol specifies type of fast operating fuse.
Precaution: Pour eviter risques de feux, remplacez
le fusible de surete de F403 comme le meme type
que 4A/125V, F504 comme le meme type que
8A/125, et 8A/125V pour F505.
Ce sont des fusibles suretes qui functionnes rapide.