SERVICE MANUAL
COPYRIGHT © 2005 Victor Company of Japan, Limited
No.MB364
2005/5
AUDIO/VIDEO CONTROL RECEIVER
MB364
2005
5
RX-D201S,RX-D202B
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
TABLE OF CONTENTS
1
PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
Area suffix
RX-D201S
J ---------------------------- U.S.A.
Area suffix
RX-D202B
J ---------------------------- U.S.A.
C ------------------------- Canada
1-2 (No.MB364)
SPECIFICATION
* Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).
Designs and specifications are subject to change without notice.
Amplifier
Output Power At stereo operation
Front channels
100 W per channel, min. RMS, driven into 6
at 40 Hz
to 20 kHz with no more than 0.8% total harmonic distor-
tion.
At surround operation
Front channels
100 W per channel, min. RMS, driven into 6
at 1 kHz
with no more than 0.8% total harmonic distortion.
Center channel
100 W, min. RMS, driven into 6
at 1 kHz, with no more
than 0.8% total harmonic distortion.
Surround channels
100 W per channel, min. RMS, driven into 6
at 1 kHz,
with no more than 0.8% total harmonic distortion.
Surround back channels
100 W per channel, min. RMS, driven into 6
at 1 kHz,
with no more than 0.8% total harmonic distortion.
Audio
Audio Input Sensitivity/Impedance
DVR/DVD, VCR, DBS, TV:270 mV/47 k
Audio Input (DIGITAL IN)*
Coaxial
DIGITAL IN 1(DVR/DVD):0.5 V(p-p)/75
Optical
DIGITAL IN 2(DBS):-21 dBm to -15 dBm (660 nm ±30
nm)
USB
USB DIGITAL
Audio Output Level
DVR, VCR:270 mV
Signal-to-Noise Ratio ('66 IHF/'78 IHF)
80 dB/62 dB
Frequency Response (6
)
20 Hz to 20 kHz (±1 dB)
Bass Boost
+4 dB ±1 dB at 100 Hz
Equalization (at DSP operation)
Center frequency
63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz
Control range
±8 dB
Video
Video Input Sensitivity/Impedance Composite video:DVR/DVD, VCR, DBS 1 V(p-p)/75
S-video:DVR/DVD, VCR, DBS
Y (luminance):1 V(p-p)/75
C (chrominance, burst):0.286 V(p-p)/75
Component:DVR/DVD, VCR (DBS)
Y (luminance):1 V(p-p)/75
PB, PR:0.7 V(p-p)/75
Video Output Level/Impedance
Composite video:DVR/DVD, VCR, DBS 1 V(p-p)/75
S-video:DVR, VCR, MONITOR OUT
Y (luminance):1 V(p-p)/75
C (chrominance, burst):0.286 V(p-p)/75
Component:MONITOR OUT
Y (luminance):1 V(p-p)/75
PB, PR:0.7 V(p-p)/75
Synchronization
Negative
FM tuner (IHF)
Tuning Range
87.5 MHz to 108.0 MHz
Usable Sensitivity
Monaural
12.8 dBf (1.2
µV/75 )
50 dB Quieting Sensitivity
Monaural
16.0 dBf (1.7
µV/75 )
Stereo
37.5 dBf (20.5
µV/75 )
Stereo Separation at REC OUT
35 dB at 1 kHz
AM tuner
Tuning Range
530 kHz to 1 710 kHz
General
Power Requirements
AC 120 V , 60 Hz
Power Consumption
150 W/200 VA (at operation)
0.9 W (in standby mode)
Dimensions (W
× H × D)
435 mm
× 91.5 mm × 360 mm
(17 3/16 inches
× 3 5/8 inches × 14 3/16 inches)
Mass
6.7 kg (14.8 lbs)
(No.MB364)1-3
SECTION 1
PRECAUTION
1.1
Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos-
es. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be per-
formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris-
tics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by us-
ing replacement components rated for higher voltage, watt-
age, etc. Replacement parts which have these special
safety characteristics are identified in the Parts List of Ser-
vice Manual. Electrical components having such features
are identified by shading on the schematics and by (
) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety charac-
teristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassem-
bling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isola-
tion check on the exposed metal parts of the product (an-
tenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
· Plug the AC line cord directly into the AC outlet. Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal parts of the cabinet, particular-
ly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage cur-
rent must not exceed 0.5mA AC (r.m.s.).
· Alternate check method
Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000
per volt or more sensitivity
in the following manner. Connect a 1,500
10W resistor
paralleled by a 0.15
µF AC-type capacitor between an
exposed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5
mA AC (r.m.s.).
1.2
Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3
Caution
Burrs formed during molding may be left over on some parts
of the chassis.
Therefore, pay attention to such burrs in the case of pre-
forming repair of this system.
1.4
Critical parts for safety
In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor (
), diode (
)
and ICP (
) or identified by the "
" mark nearby are critical
for safety. When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer.
(This regulation dose not Except the J and C version)
Good earth ground
Place this
probe on
each exposed
metal part.
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
1500
10W
0.15 F AC TYPE
1-4 (No.MB364)
1.5
Importance administering point on the safety
Caution: For continued protection against risk of
fire, replace only with same type 2 A/125 V for
F101, 2 A/125 V for F102, 6.3 A/125 V for F103.
This symbol specifies type of fast operating fuse.
Precaution: Pour eviter risques de feux, remplacez
le fusible de surete de F101 comme le meme type
que 2 A/125 V, 2 A/125 V pour F102, et 6,3 A/125V
pour F103.
Ce sont des fusibles suretes qui functionnes rapide.
^
Primary board (Forward side)
F103
Main amplifier board (Forward side)
F102
F101
(No.MB364)1-5
1.6
Caution after repairs
There are two power supply as the second power supply of the transformer.
One is a power supply for power IC(3pin), and another is a power supply for the control(5pin).
There are two power supply as the second power supply of the transformer.
One is a power supply for power IC(3pin), and another is a power supply for the control(5pin).
Please connect first of all and confirm the power supply for the control when you do the energizing examination after it completes of
the repair.
Please never do the energizing examination in a power supply of power IC alone.
Moreover, when the control system breaks down, power IC is occasionally damaged.
+B for power IC
(3pins)
+B for control section
(5pins)
For power IC(3pins)