background image
SERVICE MANUAL
COPYRIGHT © 2005 Victor Company of Japan, Limited
No.MB394
2005/7
COMPACT COMPONENT SYSTEM
MB394
2005
7
MX-KC2
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
TABLE OF CONTENTS
1
PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
CA-MXKC2
SP-MXKC2
SP-MXKC2
Area suffix
C ------------------------- Canada


background image
1-2 (No.MB394)
SPECIFICATION
Design and specifications are subject to change without notice.
Amplifier
Output Power
60 W per channel, min. RMS, driven into 6
at 1kHz, with
no more than 10% total harmonic distortion
Input Sensitivity/Impedance
(1 kHz)
AUX IN
400 mV/50 k
Speaker terminals 6 - 16
Phones
32
- 1 k
15 mW/ch output into 32
Cassette Deck Section Frequency Response Type l (NORMAL)
63 Hz - 12 500 Hz
Wow And Flutter
0.15% (WRMS)
CD Player
CD Capacity
3 CDs
Dynamic Range
83 dB
Signal-To-Noise Ratio
85 dB
Wow And Flutter
Unmeasurable
Tuner
Tuning Range
FM Tuner
87.5 MHz - 108.0 MHz
AM Tuner
530 kHz - 1 710 kHz
Unit
Dimensions
270 mm
× 308 mm × 410mm (W/H/D)
(10-11/16"
× 12-3/16" × 16-3/16")
Mass
Approx. 6.5 kg (14.4 lbs)
Speaker Specifications
(each unit)
Type
2-way bass-reflex type
Speaker Unit
Woofer
13 cm (5-1/8") cone
× 1
Tweeter
5cm (2") cone
× 1
Power Handling Capacity
60 W
Impedance
6
Frequency Range
45 Hz - 22 000 Hz
Sound pressure level
87 dB/W·m
Dimensions
205 mm
× 308 mm × 209 mm (W/H/D)
(8-1/8"
× 12-3/16" × 8-1/4")
Mass
Approx. 2.9 kg (6.4 lbs)
Power Specifications
Power Requirements
AC 120 V , 60 Hz
Power Consumption
95 W (power on mode)
13 W (in Standby mode)
1.2 W (in ECO mode)


background image
(No.MB394)1-3
SECTION 1
PRECAUTION
1.1
Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos-
es. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be per-
formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris-
tics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by us-
ing replacement components rated for higher voltage, watt-
age, etc. Replacement parts which have these special
safety characteristics are identified in the Parts List of Ser-
vice Manual. Electrical components having such features
are identified by shading on the schematics and by (
) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety charac-
teristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassem-
bling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isola-
tion check on the exposed metal parts of the product (an-
tenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
· Plug the AC line cord directly into the AC outlet. Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal parts of the cabinet, particular-
ly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage cur-
rent must not exceed 0.5mA AC (r.m.s.).
· Alternate check method
Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000
per volt or more sensitivity
in the following manner. Connect a 1,500
10W resistor
paralleled by a 0.15
µF AC-type capacitor between an ex-
posed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5
mA AC (r.m.s.).
1.2
Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3
Caution
Burrs formed during molding may be left over on some parts
of the chassis.
Therefore, pay attention to such burrs in the case of pre-
forming repair of this system.
1.4
Critical parts for safety
In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor (
), diode (
)
and ICP (
) or identified by the "
" mark nearby are critical
for safety. When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer.
(This regulation dose not Except the J and C version)
Good earth ground
Place this
probe on
each exposed
metal part.
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
1500
10W
0.15 F AC TYPE


background image
1-4 (No.MB394)
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
This service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.


background image
(No.MB394)1-5
SECTION 3
DISASSEMBLY
3.1
Disassembly of the main blocks of the set
Replacement of the fuses and the power IC.
3.1.1 Replacing the fuses
(See Fig.1)
· Prior to performing the following procedure, remove the left
side board.
(1) Replace the fuses inside.
Caution:
Be sure to use fuses with the specified ratings.
Fig.1
3.1.2 Replacing the power IC
(See Fig.2)
· Prior to performing the following procedure, remove the top
cover.
(1) Remove the two screws A from the heat sink between the
power IC.
(2) Remove the solder fixing the power IC.
Fig.2
3.1.3 Replacing the heat sink cover
(See Fig.3)
(1) Remove four screws B from the rear panel.
(2) Pull the heat sink cover outward.
Fig.3
Fuse (F901)
1.6AL 250V
W
A
B