background image
SERVICE MANUAL
COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD.
No.52068
2002/12
HV-32D25EUW
HV-32D25EJW
COLOUR TELEVISION
52068
2002
12
HV-32D25EUW
HV-32D25EJW
CONTENTS
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SERVICE ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
BASIC CHASSIS
MK


background image
HV-32D25EUW
HV-32D25EJW
2
SPECIFICATION
Item
Content
HV-32D25EUW
HV-32D25EJW
Dimensions (W x H x D)
94.6cm x 56.2cm x 55.1cm
Mass
58.0kg
TV RF System
CCIR B/G, I, D/K, L/L'
Colour System
PAL / SECAM / NTSC
*The EXT terminals also support the NTSC 3.58MHz/4.43MHz system.
Stereo System
A2 (B/G, D/K) / NICAM (B/G, I, D/K, L)
Teletext System
FLOF(Fastext), TOP, WST(World Standard system)
Receiving Frequency
VHF
UHF
CATV
47MHz ~ 470MHz
470MHz ~ 862MHz
116MHz ~ 172MHz / 220MHz ~ 469MHz
47MHz ~ 470MHz (IRELAND only)
470MHz ~ 862MHz
-
-
Intermediate Frequency VIF
SIF
38.9MHz(B/G, D/K, I) / 33.95MHz(L')
33.4MHz(5.5MHz:B/G) / 32.9MHz(6.0MHz:I) / 32.4MHz(6.5MHz:L,D/K) /
40.45MHz(6.5MHz:L')
Colour Sub Carrier
Frequency
PAL
SECAM
NTSC
4.43MHz
4.40625MHz / 4.25MHz
3.58MHz / 4.43MHz
Power Input
AC 220V~AC240V, 50Hz
Power Consumption
Max 300W / Avg. 160W
Aerial Input
75 ohm unbalanced, coaxial
Picture Tube
Visible size 76 cm(measured diagonally) Aspect ratio 16:9
High Voltage
31.0kV
0.2kV (At beam current : 0uA )
Speaker
MAIN
CENTER
WOOFER
10W + 10W, 13 cm x 6.5 cm oval x2
7.5W, 16 cm x 4 cm oval x 1
18W, 13 cm round x 1
EXT-1 (Input/Output)
21 pin Euro connector (SCART socket)
· Video input, Audio L/R inputs and RGB inputs are available.
· TV broadcast outputs (Video and Audio L/R) are available.
EXT-2 (Input/Output)
21 pin Euro connector (SCART socket)
· Video input, S-Video (Y/C) input, Audio L/R inputs and RGB inputs are available.
· Video and Audio L/R outputs are available.
· T-V LINK functions are available.
EXT-3 (Input/Output)
21 pin Euro connector (SCART socket)
· Video input, S-Video (Y/C) input and Audio L/R inputs are available.
EXT-4 (Input)
Component
video
RCA pin jack x 3
Y : 1V(p-p), 75 ohm
Pb / B-Y: 0.7V(p-p), 75 ohm
Pr / R-Y : 0.7V(p-p), 75 ohm
Progressive-scanning signals(626p or 525p) are available
Audio (L/R)
500mv(rms) (-4dBs), High Impedance RCA pin jack x 2
EXT-5 (Input)
Video
1V(p-p), 75 ohm RCA pin jack x 1
Audio (L/R)
500mv(rms) (-4dBs), High Impedance RCA pin jack x 2
S-Video
Mini DIN 4-pin
Y : 1V(p-p) Positive (Negative sync provided), 75 ohm
C : 0.286V(p-p) (burst signal), 75 ohm
DIGITAL AUDIO INPUT
OPTICAL x 1
COAXIAL x 1 (Dolby Digital is available.)
AUDIO OUT (Variable)
0~1V(rms), Low Impedance RCA pin jack x 3
SURROUND REAR OUT
7.5W + 7.5W, 8 ohm (push terminal)
Headphone jack
Stereo mini jack (Ø3.5mm)
Remote Control Unit
RM-C61 (AAA/R03 Dry cell battery x 2) : HV-32D25EUW
RM-C62 (AAA/R03 Dry cell battery x 2) : HV-32D25EJW
Design & specifications are subject to change without notice.
Manufactured under license from Dolby Laboratories Licensing Corporation.
"Dolby" and the double-D symbol (
)are trademarks of Dolby Laboratories Licensing Corporation.


background image
HV-32D25EUW
HV-32D25EJW
3
21-pin Euro connector (SCART) : EXT-1/EXT-2/EXT-3
(P-P= Peak to Peak, B-W= Blanking to white peak)
PinNo.
Signal Designation
Matching Value
EXT-1
EXT-2
EXT-3
1
AUDIO R output
500mV(rms) (Nominal),
Low impedance
Used (TV OUT)
Used (LINE OUT) NC
2
AUDIO R input
500mV(rms) (Nominal),
High impedance
Used
Used
Used
3
AUDIO L output
500mV(rms) (Nominal),
Low impedance
Used (TV OUT)
Used (LINE OUT) Not used
4
AUDIO GND
Used
Used
Used
5
GND (B)
Used
Used
Used
6
AUDIO L input
500mV(rms) (Nominal),
High impedance
Used
Used
Used
7
B input
700mV(B-W), 75 ohm
Used
Used
Not used
8
FUNCTION SW
(SLOW SW)
Low : 0V-3V, High : 8V-12V,
High impedance
Used
Used
Used
9
GND (G)
Used
Used
Used
10
SCL
Not used
Used (SCL2)
Used (SCL3)
11
G input
700mV(B-W), 75 ohm
Used
Used
Not used
12
SDA
Not used
Used(SDA2)
Used(SDA3)
13
GND (R)
Used
Used
Used
14
GND (YS)
Used
Not used
Not used
15
R / C input
R : 700mV(B-W), 75 ohm
C : 300mV(P-P), 75 ohm
Used (R)
Used (C2/R)
Used (C3)
16
Ys input
(FAST SW)
Low : 0V-0.4V, High : 1V-3V,
75 ohm
Used
Used
Not used
17
GND (VIDEO output)
Used
Used
Used
18
GND (VIDEO input)
Used
Used
Used
19
VIDEO output
1V(P-P) (Negative going sync),
75 ohm
Used (TV OUT)
Used (LINE OUT) Not used
20
VIDEO / Y input
1V(P-P) (Negative going sync),
75 ohm
Used
Used
Used
21
COMMON GND
Used
Used
Used
20
18
16
14
12
10
8
6
4
2
21
19
17
15
13
11
9
7
5
3
1
[Pin assignment]


background image
HV-32D25EUW
HV-32D25EJW
4
SECTION 1
SAFETY PRECAUTIONS
1.1 HV-32D25EUW
(1) The design of this product contains special hardware,
many circuits and components specially for safety purpos-
es. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Service should be per-
formed by qualified personnel only.
(2) Alterations of the design or circuitry of the products should
not be made. Any design alterations or additions will void
the manufacturer's warranty and will further relieve the
manufacturer of responsibility for personal injury or prop-
erty damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris-
tics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by
using replacement components rated for higher voltage,
wattage, etc. Replacement parts which have these special
safety characteristics are identified in the parts list of Ser-
vice manual. Electrical components having such fea-
tures are identified by shading on the schematics and
by (
) on the parts list in Service manual. The use of
a substitute replacement which does not have the same
safety characteristics as the recommended replacement
part shown in the parts list of Service manual may cause
shock, fire, or other hazards.
(4) Don't short between the LIVE side ground and ISO-
LATED (NEUTRAL) side ground or EARTH side
ground when repairing.
Some model's power circuit is partly different in the GND.
The difference of the GND is shown by the LIVE : (
) side
GND, the ISOLATED (NEUTRAL) : (
) side GND and
EARTH : (
) side GND.
Don't short between the LIVE side GND and ISOLATED
(NEUTRAL) side GND or EARTH side GND and never
measure the LIVE side GND and ISOLATED (NEUTRAL)
side GND or EARTH side GND at the same time with a
measuring apparatus (oscilloscope etc.).
If above note will not be kept, a fuse or any parts will be
broken.
(5) If any repair has been made to the chassis, it is recom-
mended that the B1 setting should be checked or adjusted
(See ADJUSTMENT OF B1 POWER SUPPLY).
(6) The high voltage applied to the picture tube must conform
with that specified in Service manual. Excessive high volt-
age can cause an increase in X-Ray emission, arcing and
possible component damage, therefore operation under
excessive high voltage conditions should be kept to a min-
imum, or should be prevented. If severe arcing occurs, re-
move the AC power immediately and determine the cause
by visual inspection (incorrect installation, cracked or melt-
ed high voltage harness, poor soldering, etc.). To maintain
the proper minimum level of soft X-Ray emission, compo-
nents in the high voltage circuitry including the picture tube
must be the exact replacements or alternatives approved
by the manufacturer of the complete product.
(7) Do not check high voltage by drawing an arc. Use a high
voltage meter or a high voltage probe with a VTVM. Dis-
charge the picture tube before attempting meter connec-
tion, by connecting a clip lead to the ground frame and
connecting the other end of the lead through a 10k
2W
resistor to the anode button.
(8) When service is required, observe the original lead dress.
Extra precaution should be given to assure correct lead
dress in the high voltage circuit area. Where a short circuit
has occurred, those components that indicate evidence of
overheating should be replaced.
Always use the manufacturer's replacement components.
(9) Isolation Check
(Safety for Electrical Shock Hazard)
After re-assembling the product, always perform an isola-
tion check on the exposed metal parts of the cabinet (an-
tenna terminals, video/ audio input and output terminals,
Control knobs, metal cabinet, screw heads, earphone
jack, control shafts, etc.) to be sure the product is safe to
operate without danger of electrical shock.
a) Dielectric Strength Test
The isolation between the AC primary circuit and all metal
parts exposed to the user, particularly any exposed metal
part having a return path to the chassis should withstand
a voltage of 3000V AC (r.m.s.) for a period of one second.
(. . . . Withstand a voltage of 1100V AC (r.m.s.) to an ap-
pliance rated up to 120V, and 3000V AC (r.m.s.) to an ap-
pliance rated 200V or more, for a period of one second.)
This method of test requires a test equipment not general-
ly found in the service trade.
b) Leakage Current Check
Plug the AC line cord directly into the AC outlet (do not use
a line isolation transformer during this check.). Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal part of the cabinet, particularly
any exposed metal part having a return path to the chas-
sis, to a known good earth ground (water pipe, etc.). Any
leakage current must not exceed 0.5mA AC (r.m.s.).
However, in tropical area, this must not exceed 0.2mA AC
(r.m.s.).
Alternate Check Method
Plug the AC line cord directly into the AC outlet (do not
use a line isolation transformer during this check.). Use
an AC voltmeter having 1000 ohms per volt or more sen-
sitivity in the following manner. Connect a 1500 ohm
10W resistor paralleled by a 0.15µF AC-type capacitor
between an exposed metal part and a known good earth
ground (water pipe, etc.). Measure the AC voltage across
the resistor with the AC voltmeter. Move the resistor con-
nection to each exposed metal part, particularly any ex-
posed metal part having a return path to the chassis, and
measure the AC voltage across the resistor. Now, re-
verse the plug in the AC outlet and repeat each measure-
ment. Any voltage measured must not exceed 0.75V AC
(r.m.s.). This corresponds to 0.5mA AC (r.m.s.).
However, in tropical area, this must not exceed 0.3V AC
(r.m.s.). This corresponds to 0.2mA AC (r.m.s.).
AC VOLTMETER
(HAVING 1000
/V,
OR MORE SENSITIVITY)
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
1500
10W
0.15uF AC-TYPE
GOOD EARTH GROUND


background image
HV-32D25EUW
HV-32D25EJW
5
1.2 HV-32D25EJW [UK VERSION]
(1) The design of this product contains special hardware and many circuits and components specially for safety purposes. For
continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Re-
placement parts must be identical to those used in the original circuits. Service should be performed by qualified personnel
only.
(2) Alterations of the design or circuitry of the product should not be made. Any design alterations or additions will void the manu-
facturer's warranty and will further relieve the manufacturer of responsibility for personal injury or property damage resulting
therefrom.
(3) Many electrical and mechanical parts in the product have special safety-related characteristics. These characteristics are often
not evident from visual inspection nor can the protection afforded by them necessary be obtained by using replacement com-
ponents rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified
in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics
and by (
) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety
characteristics as the recommended replacement part shown in the Parts List of Service Manual may cause shock, fire, or other
hazards.
(4) The leads in the products are routed and dressed with ties, clamps, tubing's, barriers and the like to be separated from live
parts, high temperature parts, moving parts and / or sharp edges for the prevention of electric shock and fire hazard. When
service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been
returned to normal, after re-assembling.
WARNING
(1) The equipment has been designed and manufactured to meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant safety standards.
(4) It is essential that safety critical components are replaced by approved parts.
(5) If mains voltage selector is provided, check setting for local voltage.