background image
No.52012
HV-29LPZ
1
COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD.
Jun. 2002
HV-29LPZ
HV-29LPZ/HK
HV-29LPZ/-A
HV-29LPZ/EE
CONTENTS
! SPECIFICATIONS
2
! SAFETY PRECAUTIONS
3
!
MAIN DIFFERENCE LIST
4
!
FEATURES
4
! FUNCTIONS
6
! SPECIFIC SERVICE INSTRUCTIONS
8
! SERVICE ADJUSTMENTS
14
!
PARTS LIST
37
OPERATING INSTRUCTIONS
STANDARD CIRCUIT DIAGRAM
2-1
SERVICE MANUAL
COLOUR TELEVISION
BASIC CHASSIS
MF


background image
No.52012
HV-29LPZ
2
SPECIFICATIONS
Item
Content
Dimensions ( W×
×
×
×
×
×
×
D )
73.2cm×58.7c m× 51.8cm
Mass
48.0kg
TV RF System
B/G, I, D/K, K1, M
Colour System
PAL / SECAM / NTSC 3.58 / NTSC 4.43
Stereo System
A2 (B/G) / NICAM (B/G, I, D/K, K1)
Teletext System
Fastext (UK system) *
[ * Without TEXT mode : HV-29LPZ/HK ]
WST(world s tandard Texst)
VL
46.25MHz 168.25MHz
VH
175.25MHz 463.25MHz
Receiving
Frequency
UHF
CATV
471.25MHz 863.25MHz
Mid (XZ+2, S1S10), Super (S11S20) & Hyper (S21S41)
VIF
38.0MHz
Intermediate
Frequency
SIF
32.5MHz(5.5MHz) / 32.0MHz(6.0MHz) / 3.15MHz(6.5MHz) / 33.5MHz (4.5MHz)
PAL
4.43MHz
SECAM
4.40625MHz / 4.25MHz
Colour Sub Carrier
Frequency
NT SC
3.58MHz / 4.43MHz
Power Input
AC 110V240V , 50/60Hz
Power Consumption
Max 254W / Avg. 170W
Aerial Input Term
75unbalanc ed, Coaxial
Picture Tube
29"(68c m) measured diagonally
High Voltage
31.5kV
(At zero beam current )
Au dio Power Output
20W + 20W
Speaker
10cm Round type×2 / 3.5cm Round type×2
Video
1Vp-p 75
Au dio (L/R)
500mVrms(-4dBs), High Impedance
Input
Terminal
S / Video
Y : 1V(p-p) Positive (Negative s ync provided) 75
C : 0.286V(p-p) (burst signal), 75
Comp onent Cb/Cr
Y : 1V(p-p), 75
Cb : B-Y 0.7V(p-p), 75 / Cr : R-Y 0.7V(p-p), 75
Output
Video
1V(p-p) 75
Terminal
Au dio (L/R)
500mVrms(-4dBs), Low Impedanc e
AV Compulink
Mono mini jack (3.5mm )
Headphone jack
Stereo mini jac k (3.5mm )
Remote Control Unit
RM-C214 (AA/R06 / UM-3 , Dry cell battery×2) : HV-29LPZ / HV-29LPZ/-A / HV-29LPZ/EE
RM-C215 (AA/R06 / UM-3 , Dry cell battery×2) : HV-29LPZ/HK
Design & specifications are subject to change without notice.
+1.0kV
-1.5kV


background image
No.52012
HV-29LPZ
3
SAFETY PRECAUTIONS
1. The design of this product contains special hardware, many
circuits and components specially for safety purposes. For
continued protection, no changes should be made to the original
design unless authorized in writing by the manufacturer.
Replacement parts must be identic al to thos e used in the original
circuits. Service should be performed by qualified pers onnel
only.
2. Alterations of the design or circuitry of the products should not be
made. Any design alterations or additions will void the
manufacturer's warranty and will further relieve the manufacturer
of responsibility for personal injury or property damage resulting
therefrom.
3. Many electrical and mechanical parts in the products have
special safety-related characteristics. T hese characteristics are
often not evident from visual inspection nor can the protection
afforded by them necessarily be obtained by using replacement
components rated for higher voltage, wattage, etc. Replacement
parts whic h have these special s afety characteristics are
identified in the parts list of Servic e manual. Electrical
components having su ch features are identified by shading
on the schematics and by (!
!
!
!
) on the parts list in Service
manual. The us e of a substitute replacement which does not
have the same safety characteristics as the recommended
replac ement part shown in the parts list of Service manual may
cause shock, fire, or other hazards .
4. Do n't short between the LIVE side ground and ISOL ATED
(NEUTRAL) side ground or EARTH side ground when
repairing.
Some model's power circuit is partly different in the GND. The
differenc e of the GND is shown by the LIVE : (") side GND, the
ISOLATED(NEUTRAL) : (#) side GND and EARTH : ($) side
GND. Don't short between the LIVE side GND and
ISOLATED(NEUTRAL) side GND or EARTH side GND and
never measure with a measuring apparatus (oscilloscope etc.)
the LIVE side GND and ISOLATED(NEUTRAL) side GND or
EARTH side GND at the s ame time.
If above note will not be kept, a fuse or any parts will be broken.
5. If any repair has been made to the chassis, it is recommended
that the B1 setting should be checked or adjusted (See
ADJUSTMENT OF B1 POWER SUPPLY).
6. The high voltage applied to the picture tube must conform with
that specified in Service manual. Excessive high voltage can
cause an increase in X-Ray emission, arcing and possible
component damage, therefore operation under excessive high
voltage conditions should be k ept to a minimum, or should be
prevented. If s evere arc ing occurs, remove the AC power
immediately and determine the cause by visual inspection
(incorrect installation, cracked or melted high voltage harness,
poor soldering, etc.). To maintain the proper minimum level of
soft X-Ray emission, c omponents in the high voltage circuitry
including the picture tube must be the exact replacements or
alternatives approved by the manufacturer of the c omplete
product.
7. Do not c hec k high voltage by drawing an arc. Use a high voltage
meter or a high v oltage probe with a VTVM. Discharge the
picture tube before attempting meter connection, by c onnecting
a clip lead to the ground frame and c onnecting the other end of
the lead through a 10k
2W resistor to the anode button.
8. When service is required, observe the original lead dress. Extra
prec aution should be given to assure correct lead dress in the
high voltage circuit area. W here a s hort circuit has occurred,
those components that indicate evidence of overheating should
be replaced. Always use the manufacturer's replacement
components.
9. Isolation Check
(Safety for Electrical Shock Hazard)
After re-ass embling the product, always perform an isolation
check on the exposed metal parts of the cabinet (antenna
terminals, video/audio input and output terminals, Control knobs,
metal cabinet, screwheads, earphone jack, control shafts, etc.)
to be sure the product is s afe to operate without danger of
electrical shoc k.
(1) Dielectric Strength Test
The isolation between the AC primary circuit and all metal parts
exposed to the us er, particularly any expos ed metal part having a
return path to the chass is should withs tand a voltage of 3000V
AC (r.m.s.) for a period of one sec ond.
(. . . . Withstand a voltage of 1100V AC (r.m.s.) to an applianc e
rated up to 120V, and 3000V AC (r.m.s.) to an appliance rated
200V or more, for a period of one second.)
This method of test requires a test equipment not generally found
in the servic e trade.
(2) Leakage Current Check
Plug the AC line c ord directly into the AC outlet (do not use a line
isolation transformer during this check.). Using a " Leakage
Current Tester", measure the leakage current from each exposed
metal part of the cabinet, particularly any expos ed metal part
having a return path to the chassis , to a known good earth
ground (water pipe, etc.). Any leakage current must not exceed
0.5mA AC (r.m.s.).
However, in tropic al area, this must not exceed 0.2mA AC
(r.m.s.).
"
"
"
"
Alternate Check Method
Plug the AC line c ord directly into the AC outlet (do not use a line
isolation transformer during this check.). Use an AC voltmeter
having 1000 ohms per volt or more sens itivity in the following
manner. Connec t a 1500
10W res istor paralleled by a 0.15µF
AC-type c apacitor between an exposed metal part and a known
good earth ground (water pipe, etc.). Meas ure the AC voltage
across the res istor with the AC voltmeter. Move the resistor
connec tion to each exposed metal part, particularly any exposed
metal part having a return path to the chassis, and measure the
AC voltage ac ross the res istor. Now, reverse the plug in the AC
outlet and repeat eac h measurement. Any voltage measured
must not exc eed 0.75V AC (r.m.s.). This c orresponds to 0.5mA
AC (r.m.s.).
However, in tropical area, this must not exceed 0.3V AC ( r.m.s.).
This corresponds to 0.2mA AC (r.m.s.).
0.15F AC-TYPE
1500
10W
GOOD EARTH GROUND
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
AC VOLTMETER
(HAVING 1000
/V,
OR MOR E SENSITIVITY)


background image
No. 52012
HV-29LPZ
4
MAIN DIFFERENCE LIST
!
!
!
!
Model name
Part n ame
HV-29LPZ
HV-29LPZ/HK
HV-29LPZ/-A
HV-29LPZ/EE
MICOM PWB
SMF0M901A-H2
SMF0M902A-H2
SMF0M903A-H2
SMF0M904A-H2
!
POWER CORD
QMP40D0-200J5
QMPN050-200-E2
QMPR010-200-E2
QMP40D0-200J5
!
FRONT CABI.ASSY
LC11193-008B-H
LC11193-023A-H
LC11193-008B-H
!
REAR COVER
LC10763-007B-HH
LC10763-002D-H
LC10763-007B-HH
!
RATING LABEL
LC20377-001B-H
LC20377-012B-H
LC20413-002B-H
LC20377-009B-H
!
INST BOOK
LCT1215-001A-H
LCT1217-001A-H
LCT1215-001A-H
LCT1218-001A-H
!
DIGEST MANUAL
××
LCT1216-001A-H
×
!
CONVERSION PLUG
××
QAM0055-001
×
WARRANTY CARD
×××
BT-54012-2
REMOTE CONTROL UNIT
RM-C214-1C
RM-C215-1C
RM-C214-1C
FEATURES
" New chassis design enable us e of an interac tive on screen
control.
" The TELETEXT SYSTEM has a built-in FASTEXT (UK s ystem),
and WST (world standard sys tem) system.
* Exc ept HV-29LPZ/HK.
" Pure FLAT CRT reproduc efine textured.
"
Digi Pure pro : Auto digi pure with motion picture c ompensation.
" Becaus e this TV unit corresponds to multiplex broadcast, users
can enjoy music programs and s porting events with live realism.
In addition, BILINGUAL programs can be heard in their original
language.
" Built-in ECO (ECONOMY, ECOLOGY) MODE.
In accordance with the brightness in a room, the brightness
and/or contrast of the picture can be adjusted automatic ally to
make the optimum picture which is eas y on the eye.


background image
No. 52012
HV-29LPZ
5
SYSTEM BLOCK DIAGRAM
IC 001
MICRO COMPUTER
SDA 0
SCL 0
IC 004
MEMORY
IC 301
DEF & RGB
PROCESSOR
TU0 01
TUNER
IC 101
VIDEO PROCESS
&
CODEC MAIN
IC 151
VIDEO PROCESS
&
CODEC SUB
IC 201
SAMPLE RATE
CONVERTER
IC 301
ENHANCE
IC 701
BBE CONTROL
IC 101
MULTI SOUND
PROCESSOR
IC 301
SYNC SEP PWB
IC 101
SW
TU0 01
TUNER
MAIN PWB
SDA 1
SCL 1
SDA 2
SCL 2
SYNC SEP PWB
100Hz PWB
AV SW PWB
MICOM PWB