background image
SERVICE MANUAL
COPYRIGHT © 2005 Victor Company of Japan, Limited
No.YF098
2005/6
DIGITAL VIDEO CAMERA
YF098
2005
6
GR-X5US
For disassembling and assembling of MECHANISM ASSEMBLY, refer to the SERVICE MANUAL No.86700(MECHANISM ASSEMBLY).
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
TABLE OF CONTENTS
1
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
5
TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22
GR-X5US[M5D727]


background image
1-2 (No.YF098)
SPECIFICATION
Camcorder
AC Adapter
Specifications shown are for SP mode unless otherwise indicated. E & O.E. Design and specifications subject to change without
notice.
For General
Power supply
DC 11.0 V(Using AC Adapter)
DC 7.2 V (Using battery pack)
Power consumption
Approx. 4.8 W (LCD backlight off)
Approx. 5.8 W (LCD backlight off)
Approx. 6.5 W (Maximum; when charging the battery pack)
Dimensions (W
× H × D)
88 mm
× 89 mm × 93 mm (3-1/2" x 3-9/16" × 3-11/16")
(with the LCD monitor closed)
Weight
Approx. 510g(1.2 lbs)
(without battery, cassette, memory card, lens hood and lens cap)
Approx. 590 g (1.3 lbs)
(incl. battery, cassette, memory card, lens hood and lens cap)
Operating temperature
0
°C to 40°C (32°F to 104°F)
Operating humidity
35% to 80%
Storage temperature
-20
°C to 50°C (-4°F to 122°F)
Pickup
1/4.5" (1,330,000 pixels) CCD
× 3 (3 CCD)
Lens
Video: F 1.8 to 2.4, f = 3.2 mm to 32 mm, 10:1 power zoom lens
Still: F 1.9 to 2.4, f = 4 mm to 32 mm, 8:1 power zoom lens
Filter diameter
Ø37 mm
LCD monitor
2.5" diagonally measured, LCD panel/TFT active matrix system
Speaker
Monaural
Flash
Within 2 m (6.5 ft) (recommended shooting distance)
For Digital Video
Camera
Format
DV format (SD mode)
Signal format
NTSC standard
Recording/Playback
format
Video
Digital component recording
Audio
PCM digital recording, 32 kHz 4-channel (12-bit), 48 kHz 2-channel (16-bit)
Cassette
Mini DV cassette
Tape speed
SP: 18.8 mm/s, LP: 12.5 mm/s
Maximum recording time
(using 80 min. cassette)
SP: 80 min., LP: 120 min.
For Digital Still
Camera
Storage media
SD Memory Card/MultiMediaCard
Compression system
JPEG (compatible)
Image size
5 modes (2560
× 1920 / 2048 × 1536 / 1600 × 1200 / 1280 × 960 / 640 ×
480 pixels)
Picture quality
2 modes (FINE/STANDARD)
For Connectors S
S-Video input
Y: 0.8 V to 1.2 V (p-p), 75
, analog
C: 0.2 V to 0.4 V (p-p), 75
, analog
S-Video output
Y: 1.0 V (p-p), 75
, analog
C: 0.29 V (p-p), 75
, analog
AV
Video input
0.8 V to 1.2 V (p-p), 75
, analog
Video output
1.0 V (p-p), 75
, analog
Audio input
300 mV (rms), 50 k
, analog, stereo
Audio output
300 mV (rms), 1 k
, analog, stereo
Microphone
input
Ø3.5 mm, stereo
Headphone
output
Ø3.5 mm, stereo
DV
Input/output
4-pin, IEEE 1394 compliant
USB
Mini USB-B type, USB 1.1/2.0 (Full speed) compliant
Power requirement
AC 110 V to 240 V, 50 Hz/60 Hz
Output
DC 11 V, 1 A


background image
(No.YF098)1-3
SECTION 1
PRECAUTIONS
1.1
SAFTY PRECAUTIONS
Prior to shipment from the factory, JVC products are strictly
inspected to conform with the recognized product safety and
electrical codes of the countries in which they are to be
sold.However,in order to maintain such compliance, it is equally
important to implement the following precautions when a set is
being serviced.
1.1.1 Precautions during Servicing
(1) Locations requiring special caution are denoted by labels
and inscriptions on the cabinet, chassis and certain parts of
the product.When performing service, be sure to read and
comply with these and other cautionary notices appearing
in the operation and service manuals.
(2) Parts identified by the
symbol and shaded (
) parts
are critical for safety.
Replace only with specified part numbers.
NOTE :
Parts in this category also include those specified to
comply with X-ray emission standards for products
using cathode ray tubes and those specified for
compliance with various regulations regarding
spurious radiation emission.
(3) Fuse replacement caution notice.
Caution for continued protection against fire hazard.
Replace only with same type and rated fuse(s) as
specified.
(4) Use specified internal wiring. Note especially:
· Wires covered with PVC tubing
· Double insulated wires
· High voltage leads
(5) Use specified insulating materials for hazardous live parts.
Note especially:
· Insulation Tape
· PVC tubing
·Spacers
· Insulation sheets for transistors
·Barrier
(6) When replacing AC primary side components (transformers,
power cords, noise blocking capacitors, etc.) wrap ends of
wires securely about the terminals before soldering.
Fig.1-1-1
(7) Observe that wires do not contact heat producing parts
(heatsinks, oxide metal film resistors, fusible resistors, etc.)
(8) Check that replaced wires do not contact sharp edged or
pointed parts.
(9) When a power cord has been replaced, check that 10-15
kg of force in any direction will not loosen it.
Fig.1-1-2
(10) Also check areas surrounding repaired locations.
(11) Products using cathode ray tubes (CRTs)In regard to such
products, the cathode ray tubes themselves, the high
voltage circuits, and related circuits are specified for
compliance with recognized codes pertaining to X-ray
emission. Consequently, when servicing these products,
replace the cathode ray tubes and other parts with only the
specified parts. Under no circumstances attempt to modify
these circuits.Unauthorized modification can increase the
high voltage value and cause X-ray emission from the
cathode ray tube.
(12) Crimp type wire connectorIn such cases as when replacing
the power transformer in sets where the connections
between the power cord and power trans former primary
lead wires are performed using crimp type connectors, if
replacing the connectors is unavoidable, in order to prevent
safety hazards, perform carefully and precisely according
to the following steps.
· Connector part number :E03830-001
· Required tool : Connector crimping tool of the proper
type which will not damage insulated parts.
· Replacement procedure
a) Remove the old connector by cutting the wires at a
point close to the connector.Important : Do not
reuse a connector (discard it).
Fig.1-1-3
b) Strip about 15 mm of the insulation from the ends
of the wires. If the wires are stranded, twist the
strands to avoid frayed conductors.
Fig.1-1-4
c) Align the lengths of the wires to be connected.
Insert the wires fully into the connector.
Fig.1-1-5
d) As shown in Fig.1-1-6, use the crimping tool to crimp
the metal sleeve at the center position. Be sure to
crimp fully to the complete closure of the tool.
Fig.1-1-6
e) Check the four points noted in Fig.1-1-7.
Fig.1-1-7
Power cord
cut close to connector
15 mm
Connector
Metal sleeve
1.2
5
2.0
5.5
Crimping tool
Not easily pulled free
Crimped at approx. center
of metal sleeve
Conductors extended
Wire insulation recessed
more than 4 mm


background image
1-4 (No.YF098)
1.1.2 Safety Check after Servicing
Examine the area surrounding the repaired location for damage
or deterioration. Observe that screws, parts and wires have been
returned to original positions, Afterwards, perform the following
tests and confirm the specified values in order to verify
compliance with safety standards.
(1) Insulation resistance test
Confirm the specified insulation resistance or greater
between power cord plug prongs and externally exposed
parts of the set (RF terminals, antenna terminals, video and
audio input and output terminals, microphone jacks,
earphone jacks, etc.).See table 1 below.
(2) Dielectric strength test
Confirm specified dielectric strength or greater between
power cord plug prongs and exposed accessible parts of
the set (RF terminals, antenna terminals, video and audio
input and output terminals, microphone jacks, earphone
jacks, etc.). See Fig.1-1-11 below.
(3) Clearance distance
When replacing primary circuit components, confirm
specified clearance distance (d), (d') between soldered
terminals, and between terminals and surrounding metallic
parts. See Fig.1-1-11 below.
Fig.1-1-8
(4) Leakage current test
Confirm specified or lower leakage current between earth
ground/power cord plug prongs and externally exposed
accessible parts (RF terminals, antenna terminals, video
and audio input and output terminals, microphone jacks,
earphone jacks, etc.).
Measuring Method : (Power ON)Insert load Z between
earth ground/power cord plug prongs and externally
exposed accessible parts. Use an AC voltmeter to
measure across both terminals of load Z. See Fig.1-1-9
and following Fig.1-1-12.
Fig.1-1-9
(5) Grounding (Class 1 model only)
Confirm specified or lower grounding impedance between
earth pin in AC inlet and externally exposed accessible
parts (Video in, Video out, Audio in, Audio out or Fixing
screw etc.).Measuring Method:
Connect milli ohm meter between earth pin in AC inlet and
exposed accessible parts. See Fig.1-1-10 and grounding
specifications.
Fig.1-1-10
Fig.1-1-11
Fig.1-1-12
NOTE :
These tables are unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality.
Chassis
Power cord
primary wire
d'
d
ab
c
V
A
Externally
exposed
accessible part
Z
Exposed accessible part
Grounding Specifications
AC inlet
Region
USA & Canada
Europe & Australia
Grounding Impedance (Z)
Z
0.1 ohm
Z
0.5 ohm
Earth pin
MIlli ohm meter
AC Line Voltage
Region
Japan
Europe & Australia
R
1 M /500 V DC
USA & Canada
1 M
R
12 M /500 V DC
R
10 M /500 V DC
Insulation Resistance (R)
Dielectric Strength
Clearance Distance (d), (d')
100 V
100 to 240 V
110 to 130 V
110 to 130 V
200 to 240 V
AC 1 kV 1 minute
AC 1.5 kV 1 minute
AC 1 kV 1 minute
(Class
)
(Class
)
AC 3 kV 1 minute
AC 1.5 kV 1 minute
d, d '
3 mm
d, d '
4 mm
d, d'
3.2 mm
d'
8 m m (Power cord)
d'
6 m m (Primary wire)
d
4 m m
AC Line Voltage
Region
Japan
Europe & Australia
USA & Canada
Load Z
Leakage Current (i)
a, b, c
100 V
110 to 130 V
110 to 130 V
220 to 240 V
i
1 mA rms
i
0.5 mA rms
i
0.7 mA peak
i
2 mA dc
i
0.7 mA peak
i
2 mA dc
Exposed accessible parts
Exposed accessible parts
Antenna earth terminals
Other terminals
1
1.5
2
50
0.15


background image
(No.YF098)1-5
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
This service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.