SERVICE MANUAL
COPYRIGHT © 2005 Victor Company of Japan, Limited
No.YF073
2005/2
COMPACT VHS CAMCORDER
YF073
2005
2
GR-AXM17US, GR-SXM35UC,
GR-SXM37UC, GR-SXM37US
For disassembling and assembling of MECHANISM ASSEMBLY, refer to the SERVICE MANUAL No.86700 (MECHANISM ASSEMBLY).
TABLE OF CONTENTS
1
PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17
5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22
GR-AXM17US[M5A622],
GR-SXM35UC,GR-SXM37UC,
GR-SXM37US[M5C623]
1-2 (No.YF073)
SPECIFICATION
AC Adapter
Specifications shown are for SP mode unless otherwise indicated. E & O.E. Design and specifications subject to change without notice.
General
Format
VHS (GR-AXM17US only) / S-VHS NTSC standard
Power source
DC 11 V (Using AC Adapter)
DC 6 V (Using battery pack)
Power consumption
Viewfinder on 3.5 W
LCD monitor* on
4.3 W
* Applicable models only.
Video light**
0.4 W
** GR-SXM35, GR-SXM37 only.
Signal system
NTSC-type
Video recording system Luminance
FM recording
Colour
Converted sub-carrier direct recording Conforms to VHS standard
Cassette
/
cassette
Tape speed
SP
33.35 mm/sec.(1-5/16 ips)
EP
11.12 mm/sec.(7/16 ips)
Recording time (max.)
SP
40 minutes
EP
120 minutes (with TC-40 cassette)
Operating temperature
0
°C to 40°C(32°F to 104°F)
Operating humidity
35% to 80%
Storage temperature
-20
°C to 50°C(-4°F to 122°F)
Weight
Approx. 770 g(1.7 lbs.)(GR-AXM17US only) /,774 g(1.71 lbs.)
Dimensions (W
× H × D)
81 mm
× 125 mm × 216 mm(3-1/4" × 4-15/16" × 8-9/16")
(with the LCD monitor closed and with the viewfinder fully tilted downward)
Pickup
1/6" format CCD
Lens
F1.8 f = 2.2 mm to 44 mm, 20:1 power zoom lens with auto iris and macro con-
trol filter diameter 30.5 mm(GR-AXM17US only) /
F1.8 f = 2.2 mm to 55 mm, 25:1 power zoom lens with auto iris and macro con-
trol filter diameter 30.5 mm
Viewfinder
Electronic viewfinder with 0.16(GR-AXM17US only) /0.24" black/white CRT
White balance adjustment
Auto/Manual adjustment
LCD monitor
2.50" diagonally measured LCD panel/TFT active matrix system
Speaker
Monaural
Connectors
Video
1 V (p-p), 75
unbalanced, analogue output (via Video output connector)
Audio
300 mV (rms), 1 k
, analogue output (via Audio output connector)
S-Video (GR-SXM35, GR-SXM37 only) Y : 1 V (p-p), 75
, analog output
C : 0.29 V (p-p), 75
, analog output
Power requirement
U.S.A and Canada
AC 120 V to 60 V~
Other countries
AC 110 V to 240 V~, 50 Hz/60 Hz
Output
DC 11 V, 1 A
(No.YF073)1-3
SECTION 1
PRECAUTION
1.1
SAFTY PRECAUTIONS
Prior to shipment from the factory, JVC products are strictly
inspected to conform with the recognized product safety and
electrical codes of the countries in which they are to be
sold.However,in order to maintain such compliance, it is equally
important to implement the following precautions when a set is
being serviced.
1.1.1 Precautions during Servicing
(1) Locations requiring special caution are denoted by labels
and inscriptions on the cabinet, chassis and certain parts of
the product.When performing service, be sure to read and
comply with these and other cautionary notices appearing
in the operation and service manuals.
(2) Parts identified by the
symbol and shaded (
) parts
are critical for safety.
Replace only with specified part numbers.
NOTE :
Parts in this category also include those specified to
comply with X-ray emission standards for products
using cathode ray tubes and those specified for
compliance with various regulations regarding
spurious radiation emission.
(3) Fuse replacement caution notice.
Caution for continued protection against fire hazard.
Replace only with same type and rated fuse(s) as
specified.
(4) Use specified internal wiring. Note especially:
· Wires covered with PVC tubing
· Double insulated wires
· High voltage leads
(5) Use specified insulating materials for hazardous live parts.
Note especially:
· Insulation Tape
· PVC tubing
·Spacers
· Insulation sheets for transistors
·Barrier
(6) When replacing AC primary side components (transformers,
power cords, noise blocking capacitors, etc.) wrap ends of
wires securely about the terminals before soldering.
Fig.1-1-1
(7) Observe that wires do not contact heat producing parts
(heatsinks, oxide metal film resistors, fusible resistors, etc.)
(8) Check that replaced wires do not contact sharp edged or
pointed parts.
(9) When a power cord has been replaced, check that 10-15
kg of force in any direction will not loosen it.
Fig.1-1-2
(10) Also check areas surrounding repaired locations.
(11) Products using cathode ray tubes (CRTs)In regard to such
products, the cathode ray tubes themselves, the high
voltage circuits, and related circuits are specified for
compliance with recognized codes pertaining to X-ray
emission. Consequently, when servicing these products,
replace the cathode ray tubes and other parts with only the
specified parts. Under no circumstances attempt to modify
these circuits.Unauthorized modification can increase the
high voltage value and cause X-ray emission from the
cathode ray tube.
(12) Crimp type wire connectorIn such cases as when replacing
the power transformer in sets where the connections
between the power cord and power trans former primary
lead wires are performed using crimp type connectors, if
replacing the connectors is unavoidable, in order to prevent
safety hazards, perform carefully and precisely according
to the following steps.
· Connector part number :E03830-001
· Required tool : Connector crimping tool of the proper
type which will not damage insulated parts.
· Replacement procedure
a) Remove the old connector by cutting the wires at a
point close to the connector.Important : Do not
reuse a connector (discard it).
Fig.1-1-3
b) Strip about 15 mm of the insulation from the ends
of the wires. If the wires are stranded, twist the
strands to avoid frayed conductors.
Fig.1-1-4
c) Align the lengths of the wires to be connected.
Insert the wires fully into the connector.
Fig.1-1-5
d) As shown in Fig.1-1-6, use the crimping tool to crimp
the metal sleeve at the center position. Be sure to
crimp fully to the complete closure of the tool.
Fig.1-1-6
e) Check the four points noted in Fig.1-1-7.
Fig.1-1-7
Power cord
cut close to connector
15 mm
Connector
Metal sleeve
1.2
5
2.0
5.5
Crimping tool
Not easily pulled free
Crimped at approx. center
of metal sleeve
Conductors extended
Wire insulation recessed
more than 4 mm
1-4 (No.YF073)
1.1.2 Safety Check after Servicing
Examine the area surrounding the repaired location for damage
or deterioration. Observe that screws, parts and wires have been
returned to original positions, Afterwards, perform the following
tests and confirm the specified values in order to verify
compliance with safety standards.
(1) Insulation resistance test
Confirm the specified insulation resistance or greater
between power cord plug prongs and externally exposed
parts of the set (RF terminals, antenna terminals, video and
audio input and output terminals, microphone jacks,
earphone jacks, etc.).See table 1 below.
(2) Dielectric strength test
Confirm specified dielectric strength or greater between
power cord plug prongs and exposed accessible parts of
the set (RF terminals, antenna terminals, video and audio
input and output terminals, microphone jacks, earphone
jacks, etc.). See Fig.1-1-11 below.
(3) Clearance distance
When replacing primary circuit components, confirm
specified clearance distance (d), (d') between soldered
terminals, and between terminals and surrounding metallic
parts. See Fig.1-1-11 below.
Fig.1-1-8
(4) Leakage current test
Confirm specified or lower leakage current between earth
ground/power cord plug prongs and externally exposed
accessible parts (RF terminals, antenna terminals, video
and audio input and output terminals, microphone jacks,
earphone jacks, etc.).
Measuring Method : (Power ON)Insert load Z between
earth ground/power cord plug prongs and externally
exposed accessible parts. Use an AC voltmeter to
measure across both terminals of load Z. See Fig.1-1-9
and following Fig.1-1-12.
Fig.1-1-9
(5) Grounding (Class 1 model only)
Confirm specified or lower grounding impedance between
earth pin in AC inlet and externally exposed accessible
parts (Video in, Video out, Audio in, Audio out or Fixing
screw etc.).Measuring Method:
Connect milli ohm meter between earth pin in AC inlet and
exposed accessible parts. See Fig.1-1-10 and grounding
specifications.
Fig.1-1-10
Fig.1-1-11
Fig.1-1-12
NOTE :
These tables are unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality.
Chassis
Power cord
primary wire
d'
d
ab
c
V
A
Externally
exposed
accessible part
Z
Exposed accessible part
Grounding Specifications
AC inlet
Region
USA & Canada
Europe & Australia
Grounding Impedance (Z)
Z
0.1 ohm
Z
0.5 ohm
Earth pin
MIlli ohm meter
AC Line Voltage
Region
Japan
Europe & Australia
R 1 M /500 V DC
USA & Canada
1 M
R 12 M /500 V DC
R 10 M /500 V DC
Insulation Resistance (R)
Dielectric Strength
Clearance Distance (d), (d')
100 V
100 to 240 V
110 to 130 V
110 to 130 V
200 to 240 V
AC 1 kV 1 minute
AC 1.5 kV 1 minute
AC 1 kV 1 minute
(Class )
(Class )
AC 3 kV 1 minute
AC 1.5 kV 1 minute
d, d'
3 mm
d, d'
4 mm
d, d'
3.2 mm
d'
8 m m (Power cord)
d'
6 m m (Primary wire)
d
4 m m
AC Line Voltage
Region
Japan
Europe & Australia
USA & Canada
Load Z
Leakage Current (i)
a, b, c
100 V
110 to 130 V
110 to 130 V
220 to 240 V
i
1 mA rms
i
0.5 mA rms
i
0.7 mA peak
i
2 mA dc
i
0.7 mA peak
i
2 mA dc
Exposed accessible parts
Exposed accessible parts
Antenna earth terminals
Other terminals
1
1.5
2
50
0.15
(No.YF073)1-5
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
2.1
DIFFERENCE LIST
The following table indicate main different points between models GR-AXM17US, GR-SXM35UC, GR-SXM37UC AND GR-
SXM37US.
MODEL
GR-AXM17US
GR-SXM35UC
GR-SXM37UC
GR-SXM37US
TAPE FORMAT
VHS-C
S-VHS-C
S-VHS-C
S-VHS-C
BUILT-IN LIGHT(LAMP)
NO
YES
YES
YES
A / V CABLE
YES
YES
NO
NO
CASSETTE ADAPTER
OPTIONAL
OPTIONAL
PROVIDE
(C-P8U)
PROVIDE
(C-P8U)