SERVICE MANUAL
COPYRIGHT © 2004 Victor Company of Japan, Limited
No.XA019
2004/5
DVD VIDEO RECORDER
XA019
2004
5
DR-M10SUS, DR-M10SUC
DR-M10SUJ
TABLE OF CONTENTS
1
PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2
SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
3
DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
4
ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Area Suffix
US ---------------- U.S.A.
UC -------------- Canada
UJ -------- U.S.A Militaly
Since the whole mechanism assembly unit is replaced, the DVD recorder
mechanism of this unit need not be adjusted.
CABLE/DBS
DVD
TV
DVD
CH
TIMER
REC LINK
PROG/CHECK
VCR Plus+
NEXT
PREVIOUS
PAUSE
REC
REC MODE LIVE CHECK
SET UP DISPLAY ON SCREEN
OPEN/
CLOSE
AUDIO SUBTITLE ANGLE
PROGRESSIVE
SCAN
SLOW
SLOW
PLAY/SELECT
STOP/CLEAR
NAVIGATION
TOP MENU
RETURN
ENTER
MENU
TV/CBL/DBS
STANDBY/ON
TV
MUTING
TV/
VIDEO
TV VOLUME
ABC
JKL
GHI
MNO
TUV
PQRS
WXYZ
AUX
CANCEL
MEMO/MARK
DBS
DEF
STANDBY/ON
S-VIDEO
VIDEO
L(MONO)-AUDIO-R
DV
DV IN
F1
REC MODE
PULL - OPEN
DR-M10SUS, DR-M10SUC, DR-M10SUJ
[D4R10]
1-2 (No.XA019)
SPECIFICATION
Specifications shown are for SP mode unless otherwise specified.
E.& O.E. Design and specifications subject to change without notice.
Manufactured under licence from Dolby Laboratories. "Dolby" and double-D symbol are trademarks of Dolby Laboratories.
"DTS" and "DTS Digital Out" are trademarks of Digital Theater Systems, Inc.
DR-M10SUS,DR
-M10SUC
DR-M10SUJ
GENERAL
Power requirement AC 120 V - , 60 Hz
AC 110 V -220V~, 50/60 Hz
Power consumption Power on : 34 W
Power off : 16.2 W
Power on : 37 W
Power off : 19.2 W
Temperature Operating : 5
°C to 40°C(41°F to 104°F)
Storage : -20
°C to 60°C(-4°F to140°F)
Operating position Horizontal only
Dimensions (W
× H × D) 435 mm × 70 mm × 346 mm
Weight 4.5 kg
4.0 kg
VIDEO/AUDIO
Recordable disc
DVD-RAM 12 cm : (4.7 GB/9.4 GB)
DVD-RAM 8 cm : (1.4 GB/2.8 GB)
DVD-R 12 cm:( 4.7 GB, 8 cm: 1.4 GB for General Ver. 2.0)
DVD-RW 4.7 GB for Ver. 1.0/1.1
Recording format
DVD-RAM DVD Video Recording format
DVD-R DVD-Video format
DVD-RW DVD-Video format, DVD Video Recording format
Recording time Maximum 8 hours (with 4.7 GB disc)
(XP) : Approx. 1 hour, (SP) : Approx. 2 hours, (LP) : Approx. 4 hours, (EP) : Approx. 6 hours, (FR) :
Approx. 1 hour - 8 hours
Playable disc
DVD-RAM 12 cm : (4.7 GB/9.4 GB)
DVD-RAM 8 cm : (1.4 GB/2.8 GB)
DVD-R 12 cm:( 4.7 GB, 8 cm: 1.4 GB for General Ver. 2.0)
DVD VIDEO,
DVD-RW
4.7 GB
Music CD (CD-DA)
Video CD
Super Video CD(SVCD)
CD-R/RW (CD-DA, Video CD/SVCD formatted discs)
Audio recording system Dolby Digital (2 ch)
Linear PCM (XP mode only)
Video recording compression system MPEG2 (CBR/VBR)
Input/Output
S-video input Y : 0.8 - 1.2 Vp-p, 75
C : 0.2 - 0.4 Vp-p, 75
S-video output Y : 1.0 Vp-p, 75
C : 0.3 Vp-p, 75
Video input 0.5 - 2.0 Vp-p, 75
(pin jack)
Video output 1.0 Vp-p, 75
(pin jack)
Audio input -8 dB, 50 k
(pin jack) Corresponding to mono (left)
Audio output -8 dB, 1 k
(pin jack)
i.Link 4-pin for DV input
Component video output Y : 1.0 Vp-p, 75
PB/PR : 0.7 Vp-p, 75
Corresponding to copy protection
Digital audio output Optical : -18 dBm, 660 nm
Coaxial : 0.7Vp-p,75ohms Corresponding to Dolby Digital and DTS Digital Surround
Bit stream
Selectable in digital audio output setting menu
TUNER
Tuning system Frequency synthesized tuner
Channel coverage VHF : Channels 2 - 13
UHF : Channels 14 - 69
CATV : 113 Channels
TIMER
Clock reference Quartz
Program capacity 1-year programmable timer/8 programs
Memory backup time Approx. 60 min.
ACCESSORIES
Provided accessories RF cable,Audio/video cable, Controller,Infrared
remote control unit,"AA" battery x 2
RF cable,Audio/video cable, Controller,Infrared
remote control unit,"AA" batteryx2,Conversion plug
(No.XA019)1-3
SECTION 1
PRECAUTION
1.1
Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos-
es. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be per-
formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris-
tics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by us-
ing replacement components rated for higher voltage, watt-
age, etc. Replacement parts which have these special
safety characteristics are identified in the Parts List of Ser-
vice Manual. Electrical components having such features
are identified by shading on the schematics and by (
) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety charac-
teristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassem-
bling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isola-
tion check on the exposed metal parts of the product (an-
tenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
· Plug the AC line cord directly into the AC outlet. Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal parts of the cabinet, particular-
ly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage cur-
rent must not exceed 0.5mA AC (r.m.s.).
· Alternate check method
Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000
per volt or more sensitivity
in the following manner. Connect a 1,500
10W resistor
paralleled by a 0.15
µF AC-type capacitor between an ex-
posed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5
mA AC (r.m.s.).
1.2
Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3
Caution
Burrs formed during molding may be left over on some parts
of the chassis.
Therefore, pay attention to such burrs in the case of pre-
forming repair of this system.
1.4
Critical parts for safety
In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor (
), diode (
)
and ICP (
) or identified by the "
" mark nearby are critical
for safety. When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer.
(This regulation dose not Except the J and C version)
Good earth ground
Place this
probe on
each exposed
metal part.
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
1500
10W
0.15 F AC TYPE
1-4 (No.XA019)
1.5
Preventing static electricity
Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser
diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.
1.5.1
Grounding to prevent damage by static electricity
Static electricity in the work area can destroy the optical pickup (laser diode) in devices such as DVD players.
Be careful to use proper grounding in the area where repairs are being performed.
(1) Ground the workbench
Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the
traverse unit (optical pickup) on it.
(2) Ground yourself
Use an anti-static wrist strap to release any static electricity built up in your body.
(3) Handling the optical pickup
· In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical
pickup are shorted. After replacement, return the shorted parts to their original condition.
(Refer to the text.)
· Do not use a tester to check the condition of the laser diode in the optical pickup. The tester's internal power source can easily
destroy the laser diode.
1.6
Handling the traverse unit (optical pickup)
(1) Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit.
(2) Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the
replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long
a time when attaching it to the connector.
(3) Handle the flexible cable carefully as it may break when subjected to strong force.
(4) I t is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.
(No.XA019)1-5
1.7
Important for laser products
D5101
D5102
D5105
D5106
D5201
D5212
Q5313
D5308
D5311
PC5101
C5003
CN5303
CN5302
CN5301
F5001
CP5301
T5001
R5314
D5202
D5203
D5204
D5209
D5309
D5310
IC5101
B5001
C5001
C5002
C5004
C5005
C5101
C5102
C5103
C5104
C5105
C5201
C5202
C5203
C5204
C5205
C5206
C5207
C5208
C5209
B5302
C5211
C5301
C5302
C5304
C5305
C5306
C5307
C5308
C5309
C5310
C5311
C5312
C5315
C5316
C5317
D5315
C5321
C5322
C5323
W5313
W5314
W5306
C5330
C5332
CN5001
CN5304
CN5305
D5001
D5103
D5104
W5307
D5205
D5206
D5207
D5208
D5211
W5308
D5214
D5301
D5302
D5303
D5304
D5305
D5306
D5307
D5312
D5313
D5314
FC5001
FC5002
IC5301
IC5302
W5309
K5102
L5201
L5202
L5203
L5204
L5205
L5206
R5307
L5208
W5311
W5312
LF5002
Q5305
R5308
Q5308
Q5310
Q5315
Q5316
R5001
R5101
R5103
R5105
R5108
R5310
R5331
R5327
R5328
ST1
R5333
VA5001
VA5003
W5301
W5302
W5303
W5304
W5305
W5401
W5402
W5403
W5404
W5405
W5406
W5408
W5409
W5410
W5411
W5412
W5413
W5414
W5415
W5416
W5417
W5418
W5419
W5420
W5421
W5422
W5423
D5210
B5301
W5407
D5316
B5303
D5317
B5304
D5318
ST2
Full Fuse Replacement Marking
Graphic symbol mark
(This symbol means fast blow type fuse.)
should be read as follows ;
FUSE CAUTION
FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE, REPLACE ONLY WITH SAME TYPE
AND RATING OF FUSES ;
F5001 : 1.6 A / 250 V
F5001 : 1.6 A / 250 V
Marquage Pour Le Remplacement
Complet De Fusible
PRECAUTIONS SUR LES FUSIBLES
POUR UNE PROTECTION CONTINUE CONTRE
DES RISQUES D'INCENDIE, REMPLACER
SEULEMENT PAR UN FUSIBLE DU MEME TYPE ;
Le symbole graphique (Ce symbole signifie
fusible de type a fusion rapide.)
doit etre interprete comme suit ;
Importance administering point on the safety