background image
(WITHOUT PRICE)
SERVICE MANUAL
& PARTS LIST
REF. NO. S/M-531
JUN 1996
QW-1545
MODULE NO.
R
DW-5600E
(QW-1545)


background image
- 1 -
CONTENTS
Function
· Shock resistant (G-SHOCK)
· Electro-luminescent backlight
· Stopwatch
Measuring capacity: 23:59'59.99"
Measuring unit: 1/100 sec. (for the first 60 min.)
1 sec. (after 60 min.)
Measuring mode: Net time, split time, 1st-2nd place times
· Countdown alarm
Input range: 1 sec. to 24 hr.
Unit: 1 sec.
Other: Auto-repeat function, repeat function
· Regular timekeeping: Hr, min, sec, pm, mo, date, day
· Auto-calendar (pre-programmed until the year 2039)
· 12/24-hour formats
· Multi-function alarm
· Hourly time signals
1. SPECIFICATIONS
Notes: CONDITION OF BATTERY LIFE
Condition
Alarm
EL
20 sec/day
24 months
3.5 sec~ 1 time/day
Battery Life
Alarm
EL
20 sec/day
16 months
3.5 sec~ 5 times/day
Alarm
EL
20 sec/day
10 months
3.5 sec~ 10 times/day
1. SPECIFICATIONS · · · · · · · · · · · · · · · · · · · · · · · · · · · 1
2. OPERATION CHART · · · · · · · · · · · · · · · · · · · · · · · · · 2
3. DRAWINGS · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 4
3-1. BLOCK DIAGRAM · · · · · · · · · · · · · · · · · · · · · · · · · 4
3-2. CHECKING TERMINALS AND COMPONENTS · · · · 5
4. EXPLODED VIEW · · · · · · · · · · · · · · · · · · · · · · · · · · · 6
5. PARTS LIST · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 7
6. PRECAUTIONS FOR REPAIR · · · · · · · · · · · · · · · · · · · 8
6-1. AC (ALL CLEAR) AND REMOVING OF MODULE · · · 8
6-2. ACCURACY CHECKING · · · · · · · · · · · · · · · · · · · · 8
Item
Detail
Item
Detail
Battery
CR-2016
Accuracy
±15sec./month
Battery life
Approx. 24 months
Accuracy setting system Trimmer capacitor
Current consumption
1.98
µA maximum
Accuracy checking
See page 8
Accuracy setting
+0.25~+0.35sec./day


background image
- 2 -
2. OPERATION CHART:MODULE QW-1545


background image
- 3 -


background image
- 4 -
3. DRAWINGS: MODULE QW-1545
3-1. BLOCK DIAGRAM