1. SPECIFICATIONS ......................................................................................... 1
2. OPERATION CHART
2-1. MODULE QW-1443 ............................................................................................
3
2-2. MODULE QW-1524 ............................................................................................
8
2-3. MODULE QW-1595 .........................................................................................
12
2-4. MODULE QW-1596 .........................................................................................
14
3. DRAWINGS: MODULE QW-1443/1524/1595/1596
3-1. BLOCK DIAGRAM ..........................................................................................
16
3-2. CHECKING TERMINALS ................................................................................
20
4. EXPLODED VIEW: MODULE QW-1443/1524/1595/1596 ........................... 22
5. PARTS LIST: MODULE QW-1443/1524/1595/1596 .................................... 23
6. PRECAUTIONS FOR REPAIR: MODULE QW-1443/1524/1595/1596
6-1. AC (ALL CLEAR) AND REMOVING OF MODULE ........................................
25
6-2. ACCURACY CHECKING ................................................................................
26
6-3. BATTERY REPLACEMENT ...........................................................................
26


background image
-- 1 --
QW-1443
QW-1524
QW-1595
QW-1596
Battery
CR2016
Battery life
Approx. 1.5 years
Approx. 2 years
Current consumption
3.00
µA maximum 2.96 µA maximum
1.64
µA maximum
4.62
µA maximum
Alarm system
Piezo plate on Back cover
Accuracy
±15 sec./month
Accuracy setting system
Trimmer capacitor
Accuracy checking
See page 26
Accuracy setting
+0.25 ~ +0.35 sec./day
Functions
QW-1443
· Shock resistant (G-SHOCK)
· Low temperature resistance (-20
°C/-4 °F)
· Electro-luminescent backlight
· Contact Code function
Memory capacity: up to 100 sets of data, each set including name (8 characters)
and telephone number (12 digits)
Other: Auto sort function, remaining memory display
· Mission Code function
Memory capacity: up to 100 sets of data, each set including; month, date, hour,
minutes, and text (11 characters)
*
Memories shared between Contact Code and Mission Code
· Morse Code function
Conversion between Morse code and text/numbers: Tone/backlight
Morse code output
· Vital Statistics/ID function
Name (16 characters), blood type (Rh factor/ABO type), date of birth (year,
month, date), Credit Card Number (built-in title, 8 characters and 12 digits),
License Number (built-in title, 8 characters and 12 digits), Passport Number
(built-in title, 8 characters and 12 digits), Two undefined items (8 characters and
12 digits)
· 1/100 sec. stopwatch
Measuring capacity: 23:59'59.99"
Measuring mode: Net time, split time, 1st-2nd place times
· Regular timekeeping: Hr, min, sec, pm, yr, mo, date, day
· Auto-calendar (Pre-programmed until the year 2039)
· 12/24-hour formats
· Daily alarm
· Hourly time signals
Detail
Item
1. SPECIFICATIONS


background image
-- 2 --
Functions
QW-1524
· Shock resistant (G-SHOCK)
· Low temperature resistance (-20
°C/-4 °F)
· Electro-luminescent backlight
· 100 pages of Telememo
8 letters and 12 numerals can be memorized.
Other: Auto sort function, remaining memory display
· 100 pages of Schedule-memo
11-letter message, month, date, hour and minute per page
*
Memories shared between Telememo and Schedule-memo
· Vital Statistics/ID function
Name (16 characters), blood type (Rh factor/ABO type), date of birth (year,
month, date), Credit Card Number (built-in title, 8 characters and 12 digits),
License Number (built-in title, 8 characters and 12 digits), Passport Number
(built-in title, 8 characters and 12 digits), Two undefined items (8 characters and
12 digits)
· 1/100 sec. stopwatch
Measuring capacity: 23:59'59.99"
Measuring mode: Net time, split time, 1st-2nd place times
· Regular timekeeping: Hr, min, sec, pm, yr, mo, date, day
· Auto-calendar (Pre-programmed until the year 2039)
· 12/24-hour formats
· Daily alarm
· Hourly time signals
QW-1595
· Shock resistant (G-SHOCK)
· Electro-luminescent backlight
· Stopwatch
Measuring capacity: 23:59'59.99"
Measuring unit: 1/100 sec. (for the first 60 min.) 1sec. (after 60 min.)
Measuring mode: Net time, split time, 1st-2nd place times
· Regular timekeeping: Hr, min, sec, pm, mo, date, day
· Auto-calendar (Pre-programmed until the year 2039)
· 12/24-hour formats
· Daily alarm
· Hourly time signals
QW-1596
· Shock resistant (G-SHOCK)
· Low temperature resistance (-20
°C/-4 °F)
· Electro-luminescent backlight
· 1/100 sec. stopwatch
Measuring capacity: 23:59'59.99"
Measuring mode: Net time, split time, 1st-2nd place times
· Countdown alarm
Input range: 1 min. to 24 hr.
Unit: 1 sec.
Auto-repeat function
· Regular timekeeping: Hr, min, sec, pm, mo, date, day
· Auto-calendar (Pre-programmed until the year 2039)
· 12/24-hour formats
· Multi-function alarm
· Hourly time signals


background image
-- 3 --
2. OPERATION CHART
2-1. MODULE QW-1443